Automated vortex-assisted-liquid-liquid microextraction with injector-based derivatization for GC-MS/MS analysis of 1,3-dichloropropan-2-ol and 3-chloropropane-1,2-diol in food contact paper products
Analytical and Bioanalytical Chemistry · 2025
DOI: 10.1007/s00216-025-06133-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Malte Hübschen und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstraße 5, 45141, Essen, Germany. Hauptthemen laut MEDLINE: Liquid Phase Microextraction, alpha-Chlorohydrin, Gas Chromatography-Mass Spectrometry, Paper. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Axel Semrau GmbH, Universität Duisburg-Essen.
Abstract (Originalsprache)
The analysis of 1,3-dichloropropan-2-ol (1,3-DCP) and 3-chloropropane-1,2-diol (3-MCPD) in paper products and cardboard boxes used as food contact materials is of great importance due to the potential health risks associated with the intake of these contaminants. Both compounds, which originate from wet strength agents used in paper production, pose significant health concerns: 1,3-DCP and 3-MCPD are classified as possibly carcinogenic to humans and suspected to be carcinogenic in humans, respectively. This study presents a novel, automated analytical method for the analysis of a cold water extract—a widely used procedure for isolating these analytes from paper products and cardboard boxes. Method development included the implementation of vortex-assisted liquid-liquid microextraction (VALLME) with a focus on reducing solvent consumption and improving environmental sustainability and the systematic investigation of derivatization techniques. Optimization of the extraction solvent, extraction time, and derivatization parameters using vial-based and injector-based approaches resulted in a lean and rapid method with low limits of detection (0.01 µg/L for 1,3-DCP and 0.16 µg/L for 3-MCPD). The method showed good precision with intra-day repeatabilities of 3.6–3.7% for 1,3-DCP and 3.6–5.9% for 3-MCPD and inter-day repeatabilities of 2.6–3.6% and 4.0–7.6%, respectively. Recoveries ranged from 100 to 102% for 1,3-DCP and from 90 to 99% for 3-MCPD. Comparative assessment with a reference method confirmed good precision and comparability of the method. Improved environmental performance was quantified by the analytical greenness metric for sample preparation. Graphical abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstraße 5, 45141, Essen, Germany.
- Axel Semrau GmbH, Stefansbecke 42, 45549, Sprockhövel, Germany.
- CVUA-MEL, Joseph-König-Straße 40, 48147, Münster, Germany.
- Faculty of Chemistry, Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstraße 5, 45141, Essen, Germany. torsten.schmidt@uni-due.de.
Förderung
- Axel Semrau GmbH
- Universität Duisburg-Essen
Zitieren
APA
Hübschen, M., Brenz, F., & Schmidt, T. C. (2025). Automated vortex-assisted-liquid-liquid microextraction with injector-based derivatization for GC-MS/MS analysis of 1,3-dichloropropan-2-ol and 3-chloropropane-1,2-diol in food contact paper products. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-06133-2
Vancouver
Hübschen M, Brenz F, Schmidt TC. Automated vortex-assisted-liquid-liquid microextraction with injector-based derivatization for GC-MS/MS analysis of 1,3-dichloropropan-2-ol and 3-chloropropane-1,2-diol in food contact paper products. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-06133-2
BibTeX
@article{Hbschen2025,
author = {Hübschen, Malte and Brenz, Fabrian and Schmidt, Torsten C},
title = {Automated vortex-assisted-liquid-liquid microextraction with injector-based derivatization for GC-MS/MS analysis of 1,3-dichloropropan-2-ol and 3-chloropropane-1,2-diol in food contact paper products},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
doi = {10.1007/s00216-025-06133-2}
}
EUVIMED