Gas chromatography-triple quadrupole mass spectrometry method for analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans: evaluation and application to sediment samples
Analytical and Bioanalytical Chemistry · 2025-11 · 417 (28) · 6391-6401
DOI: 10.1007/s00216-025-06129-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 14.10.2025. Verfasst von Xuyen Thi Nguyen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 44 Literaturangaben. Gefördert von: Vingroup Innovation Foundation.
Abstract (Originalsprache)
A study was conducted to validate the gas chromatography-triple quadrupole mass spectrometry (GC-QqQ-MS) method as a cost-effective method for the analysis of polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDD/Fs) in sediment samples. The instrument sensitivity for 17 PCDD/Fs congeners was determined to be in the range of 0.201 to 1.45 ng/mL. The four-point calibration curve exhibited high linearity, with the mean relative response factors (RRFs) for PCDD/Fs ranging from 0.81 to 1.88, and RSD < 20% met the analytical requirements of the standard method for gas chromatography combined with high-resolution mass spectrometry (GC-HRMS). The quantification limit of PCDD/Fs in sediments analyzed by the GC-QqQ-MS method was demonstrated to be 2 to 21 times higher than that of the GC-HRMS method. The results of PCDD/Fs concentration analysis in sediment matrix for 1 certified reference material sample, 3 international proficiency test samples, and 29 marine sediment samples between the two analytical methods showed a relatively good agreement, with a relative difference of ± 25%. Furthermore, the gas chromatography method using triple quadrupole mass spectrometry can be regarded as a viable alternative to high-resolution mass spectrometry for sediment samples with total mass concentrations of PCDD/Fs in the 500-1000 pg/g range, and especially areas at risk of PCDD/Fs contamination.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Center for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam.
- Graduate University of Science and Technology, Vietnam Academy of Science and Technology, Hanoi, Vietnam.
- Faculty of Chemistry, University of Science, Vietnam National University, Hanoi, Hanoi, Vietnam.
- School of Chemistry and Life Sciences, Hanoi University of Science and Technology, Hanoi, Vietnam.
- Center for High Technology Research and Development, Vietnam Academy of Science and Technology, Hanoi, Vietnam. vuducnam@gmail.com.
Förderung
- Vingroup Innovation Foundation
Zitieren
APA
Nguyen, X. T., Mai, H. T. H., Dam, A. D., Nguyen, D. T., Tu, M. B., Chu, B. D., & Vu, N. D. (2025). Gas chromatography-triple quadrupole mass spectrometry method for analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans: evaluation and application to sediment samples. Analytical and Bioanalytical Chemistry, 417(28), 6391-6401. https://doi.org/10.1007/s00216-025-06129-y
Vancouver
Nguyen XT, Mai HTH, Dam AD, Nguyen DT, Tu MB, Chu BD, et al. Gas chromatography-triple quadrupole mass spectrometry method for analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans: evaluation and application to sediment samples. Analytical and Bioanalytical Chemistry. 2025;417(28):6391-6401. doi:10.1007/s00216-025-06129-y
BibTeX
@article{Nguyen2025,
author = {Nguyen, Xuyen Thi and Mai, Hang Thi Hong and Dam, Anh Duc and Nguyen, Dat Tien and Tu, Minh Binh and Chu, Binh Dinh and Vu, Nam Duc},
title = {Gas chromatography-triple quadrupole mass spectrometry method for analysis of polychlorinated dibenzo-p-dioxins, dibenzofurans: evaluation and application to sediment samples},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
volume = {417},
number = {28},
pages = {6391--6401},
doi = {10.1007/s00216-025-06129-y}
}
EUVIMED