Development of smartphone-based AIE fluorescence-quenching immunochromatographic sensors for the detection of illicit drugs in various complex sample matrices
Analytical and Bioanalytical Chemistry · 2025-11 · 417 (27) · 6165-6177
DOI: 10.1007/s00216-025-06106-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 11.09.2025. Verfasst von Lijiao Liu und 9 weiteren Autor:innen. Beteiligte Einrichtung: GuangDong Engineering Technology Research Center of Antibody Drug and Immunoassay, Department of Biological Sciences and Biotechnology, College of Li…. Hauptthemen laut MEDLINE: Illicit Drugs, Smartphone, Substance Abuse Detection, Fluorescence Resonance Energy Transfer. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Guangzhou Science and Technology Program, the Fundamental Research Funds for the Central Universities, Young Talents Support Program - Seedling Cultivation Program (Class C) at the College of Life Science and Technology, Jinan University.
Abstract (Originalsprache)
Illicit drug abuse poses a significant global threat to public health and social security, highlighting the urgent need for rapid, sensitive, and versatile detection technologies. To address the limitations of traditional chromatographic techniques-such as high costs and slow response times-and the drawbacks of conventional immunochromatographic sensors (ICS), including low sensitivity and non-intuitive signal outputs, a fluorescence-quenching ICS (FQICS) was developed. This sensor leverages fluorescence resonance energy transfer (FRET) between aggregation-induced emission fluorescent microspheres (AIEFMs) and gold nanoparticles (AuNPs). The ICS operates on a positive signal-readout mechanism and is integrated with a smartphone-based portable reader, enabling rapid quantitative detection of methamphetamine (MET), morphine (MOR), and ketamine (KET). Detection limits of 0.041, 0.072, and 0.059 ng mL-1 were determined for MET, MOR, and KET, respectively. Recovery rates ranged from 73% to 134% across urine, hair, saliva, and sewage samples, with intra-assay precision consistently below 15%, indicating robust performance in complex matrices. Furthermore, we developed a multiplexed AIEFM-FQICS, enabling the simultaneous detection of three illicit drugs, thereby enhancing detection efficiency and reducing the cost. Generally, this work presents a highly sensitive, field-deployable platform for real-time monitoring in drug interdiction and public safety emergencies, offering substantial potential for practical anti-drug applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- GuangDong Engineering Technology Research Center of Antibody Drug and Immunoassay, Department of Biological Sciences and Biotechnology, College of Life Science and Technology, Jinan University, Guangzhou, 510632, China.
- Guangdong Zhongxin Biotech Limited, Guangzhou, 510000, China.
- GuangDong Engineering Technology Research Center of Antibody Drug and Immunoassay, Department of Biological Sciences and Biotechnology, College of Life Science and Technology, Jinan University, Guangzhou, 510632, China.…
Förderung
- Guangzhou Science and Technology Program
- the Fundamental Research Funds for the Central Universities
- Young Talents Support Program - Seedling Cultivation Program (Class C) at the College of Life Science and Technology, Jinan University
Zitieren
APA
Liu, L., He, G., Ye, L., He, Y., Xu, T., Zhang, X., Zeng, C., Song, Q., Liang, J., & Tang, Y. (2025). Development of smartphone-based AIE fluorescence-quenching immunochromatographic sensors for the detection of illicit drugs in various complex sample matrices. Analytical and Bioanalytical Chemistry, 417(27), 6165-6177. https://doi.org/10.1007/s00216-025-06106-5
Vancouver
Liu L, He G, Ye L, He Y, Xu T, Zhang X, et al. Development of smartphone-based AIE fluorescence-quenching immunochromatographic sensors for the detection of illicit drugs in various complex sample matrices. Analytical and Bioanalytical Chemistry. 2025;417(27):6165-6177. doi:10.1007/s00216-025-06106-5
BibTeX
@article{Liu2025,
author = {Liu, Lijiao and He, Guanbo and Ye, Lifang and He, Yong and Xu, Tao and Zhang, Xiaoli and Zeng, Chenxing and Song, Qifang and Liang, Jiajie and Tang, Yong},
title = {Development of smartphone-based AIE fluorescence-quenching immunochromatographic sensors for the detection of illicit drugs in various complex sample matrices},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
volume = {417},
number = {27},
pages = {6165--6177},
doi = {10.1007/s00216-025-06106-5}
}