Asymmetric volume-mediated buffer control overcomes sensitivity limits in one-pot RAA-CRISPR/Cas12a visual detection
Analytical and Bioanalytical Chemistry · 2025
DOI: 10.1007/s00216-025-06095-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Yue Zhang und 12 weiteren Autor:innen. Beteiligte Einrichtung: School of Biological Science and Engineering, Shaanxi University of Technology, Hanzhong, 723000, China. Hauptthemen laut MEDLINE: CRISPR-Cas Systems, Nucleic Acid Amplification Techniques, Recombinases, Endodeoxyribonucleases. Die Arbeit nennt 36 Literaturangaben.
Abstract (Originalsprache)
Rapid, low-cost, and visual nucleic acid detection methods are highly attractive for curbing colistin resistance spread through the food chain. CRISPR/Cas12a combined with recombinase-aided amplification (RAA) offers a one-pot, aerosol-free approach for visual detection. However, traditional one-pot systems often run Cas12a trans-cleavage in a buffer suitable for RAA, thus limiting Cas12a cleavage efficiency. This study proposes an asymmetric volume-optimized RAA-CRISPR/Cas12a assay for ultrasensitive visual detection of mobile colistin resistance gene mcr-1. Unlike conventional one-pot systems constrained by buffer incompatibility, our design spatially segregates a minimal-volume RAA-MIX (lid) from a CRISPR-dominant buffer microenvironment (tube bottom). This architecture leverages RAA's exponential amplification power to ensure sufficient product yield from minimal reaction volumes, while enabling subsequent enhancement of Cas12a trans-cleavage through automatic buffer assimilation upon mixing. The results were able to be visually observed under UV light, achieving 63.1% cost reduction compared to standard one-pot methods. The sensitivity of the proposed method for the mcr-1 gene was 2.5 copies/reaction, with anti-interference against other plasmids or bacteria. This method was applied to the detection of mcr-1 in animal-derived foods, showing satisfactory practical performance. By fundamentally reengineering buffer microenvironments through volume asymmetry, this work provides a general strategy for one-pot molecular diagnostics, achieving dual optimization of amplification and cleavage without trade-offs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Biological Science and Engineering, Shaanxi University of Technology, Hanzhong, 723000, China.
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Military Medical Sciences Academy, Tianjin, 300050, China.
- School of Biological Science and Engineering, Shaanxi University of Technology, Hanzhong, 723000, China. chenwang@snut.edu.cn.
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Military Medical Sciences Academy, Tianjin, 300050, China. wujinlch@163.com.
- Tianjin Key Laboratory of Risk Assessment and Control Technology for Environment and Food Safety, Military Medical Sciences Academy, Tianjin, 300050, China. baijialeitj@163.com.
Zitieren
APA
Zhang, Y., Zhao, Z., Liu, M., Yang, J., Yang, C., Su, N., Sun, J., Fang, Y., Wang, Y., Li, X., Chen, W., Wu, J., & Bai, J. (2025). Asymmetric volume-mediated buffer control overcomes sensitivity limits in one-pot RAA-CRISPR/Cas12a visual detection. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-06095-5
Vancouver
Zhang Y, Zhao Z, Liu M, Yang J, Yang C, Su N, et al. Asymmetric volume-mediated buffer control overcomes sensitivity limits in one-pot RAA-CRISPR/Cas12a visual detection. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-06095-5
BibTeX
@article{Zhang2025,
author = {Zhang, Yue and Zhao, Zunquan and Liu, Mingzhu and Yang, Jincai and Yang, Chun and Su, Nan and Sun, Jingran and Fang, Yanjun and Wang, Yonghui and Li, Xiaoli and Chen, Wang and Wu, Jin and Bai, Jialei},
title = {Asymmetric volume-mediated buffer control overcomes sensitivity limits in one-pot RAA-CRISPR/Cas12a visual detection},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
doi = {10.1007/s00216-025-06095-5}
}
EUVIMED