PAT for monitoring the state of control in continuous manufacturing of solid oral dosage forms
Analytical and Bioanalytical Chemistry · 2025-10 · 417 (25) · 5597-5609
DOI: 10.1007/s00216-025-06012-w ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 21.07.2025. Verfasst von Nathaly A Movilla-Meza und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Puerto Rico at Mayaguez, PO Box 9000, Mayaguez, Puerto Rico, 00681, USA. Hauptthemen laut MEDLINE: Technology, Pharmaceutical. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 63 Literaturangaben. Gefördert von: Puerto Rico Science Technology & Research Trust, National Institute for Pharmaceutical Technology & Education (NIPTE) & Food and Drug Administration.
Abstract (Originalsprache)
Process analytical technology plays an important role in maintaining the state of control during pharmaceutical manufacturing processes. This review discusses different studies where continuous manufacturing runs were monitored up to 120 h. This set of studies have used near infrared spectroscopy to determine the drug concentration and confirm whether the pharmaceutical products are within specifications. The performance of these methods was evaluated through validations that included accuracy, precision, linearity, and robustness tests. The importance of the repeatability study is emphasized in this review. Different sampling locations have been shown to be useful for real-time monitoring. Process analytical technology and residence time distribution models have enabled the detection of non-conforming material and its diversion from the manufacturing process. The use of variographic analysis for improving process analytical technology implementation is discussed, since it is the only method that differentiates process variability from sampling and analytical errors. The studies discussed in this review have contributed to the improvement of the continuous manufacturing processes, providing a high level of product and process understanding, product quality, and reliability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry, University of Puerto Rico at Mayaguez, PO Box 9000, Mayaguez, Puerto Rico, 00681, USA.
- Department of Chemical Engineering, University of Puerto Rico at Mayaguez, Mayaguez, Puerto Rico, USA.
- Department of Chemistry, University of Puerto Rico at Mayaguez, PO Box 9000, Mayaguez, Puerto Rico, 00681, USA. rodolfoj.romanach@upr.edu.
Förderung
- Puerto Rico Science Technology & Research Trust
- National Institute for Pharmaceutical Technology & Education (NIPTE) & Food and Drug Administration
Zitieren
APA
Movilla-Meza, N. A., Patel, D. S., Méndez, R., & Romañach, R. J. (2025). PAT for monitoring the state of control in continuous manufacturing of solid oral dosage forms. Analytical and Bioanalytical Chemistry, 417(25), 5597-5609. https://doi.org/10.1007/s00216-025-06012-w
Vancouver
Movilla-Meza NA, Patel DS, Méndez R, Romañach RJ. PAT for monitoring the state of control in continuous manufacturing of solid oral dosage forms. Analytical and Bioanalytical Chemistry. 2025;417(25):5597-5609. doi:10.1007/s00216-025-06012-w
BibTeX
@article{MovillaMeza2025,
author = {Movilla-Meza, Nathaly A and Patel, Dhavalkumar S and Méndez, Rafael and Romañach, Rodolfo J},
title = {PAT for monitoring the state of control in continuous manufacturing of solid oral dosage forms},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
volume = {417},
number = {25},
pages = {5597--5609},
doi = {10.1007/s00216-025-06012-w}
}
EUVIMED