Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies
Analytical and Bioanalytical Chemistry · 2025
DOI: 10.1007/s00216-025-05946-5 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Marco Giulio Rozio und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Extractables & Leachables and Packaging Testing, Eurofins BPT, Via Buozzi 2, 20055, Vimodrone, MI, Italy. Hauptthemen laut MEDLINE: Drug Packaging, Drug Contamination. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
The transfer of chemicals from packaging or medical devices to drug formulations, known as extractables and leachables (E&L) release, can affect drug strength and safety. These released substances must be monitored and assessed through toxicological evaluation. Identifying and quantifying analytes above a specific analytical evaluation threshold (AET) is crucial, but variability in response factors (RFs) complicates accurate detection, leading to potential errors in quantitation. An uncertainty factor (UF) can partially correct this, though it is limited by RF variability, and a multidetector approach improves characterization but does not fully resolve quantitation bias. The RRFlow model proposed in this study offers a solution by determining E&L concentrations without real-time reference standards analysis. It involves identity confirmation, RRF validation, and applies an average corrective factor (RRFi). A numerical simulation benchmark (NSB) is used to compare different scenarios, such as varying UF values, RRFlow application, and fixed rescaling factors. The benchmark assigns concentration values to model compounds with different response factors, iterating the process to evaluate the number of false positive and negative errors. The numerical simulations show that RRFlow reduces detection bias and outperforms UF-based methods, mitigating false positives and negatives.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Extractables & Leachables and Packaging Testing, Eurofins BPT, Via Buozzi 2, 20055, Vimodrone, MI, Italy.
- Department of Extractables & Leachables and Packaging Testing, Eurofins BPT, Via Buozzi 2, 20055, Vimodrone, MI, Italy. simone.carrara@bpt.eurofinseu.com.
Zitieren
APA
Rozio, M. G., Angelini, D., & Carrara, S. (2025). Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-05946-5
Vancouver
Rozio MG, Angelini D, Carrara S. Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-05946-5
BibTeX
@article{Rozio2025,
author = {Rozio, Marco Giulio and Angelini, Davide and Carrara, Simone},
title = {Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
doi = {10.1007/s00216-025-05946-5}
}
EUVIMED