EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies

Marco Giulio Rozio, Davide Angelini, Simone Carrara

Analytical and Bioanalytical Chemistry · 2025

DOI: 10.1007/s00216-025-05946-5 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Marco Giulio Rozio und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Extractables & Leachables and Packaging Testing, Eurofins BPT, Via Buozzi 2, 20055, Vimodrone, MI, Italy. Hauptthemen laut MEDLINE: Drug Packaging, Drug Contamination. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The transfer of chemicals from packaging or medical devices to drug formulations, known as extractables and leachables (E&L) release, can affect drug strength and safety. These released substances must be monitored and assessed through toxicological evaluation. Identifying and quantifying analytes above a specific analytical evaluation threshold (AET) is crucial, but variability in response factors (RFs) complicates accurate detection, leading to potential errors in quantitation. An uncertainty factor (UF) can partially correct this, though it is limited by RF variability, and a multidetector approach improves characterization but does not fully resolve quantitation bias. The RRFlow model proposed in this study offers a solution by determining E&L concentrations without real-time reference standards analysis. It involves identity confirmation, RRF validation, and applies an average corrective factor (RRFi). A numerical simulation benchmark (NSB) is used to compare different scenarios, such as varying UF values, RRFlow application, and fixed rescaling factors. The benchmark assigns concentration values to model compounds with different response factors, iterating the process to evaluate the number of false positive and negative errors. The numerical simulations show that RRFlow reduces detection bias and outperforms UF-based methods, mitigating false positives and negatives.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Drug PackagingDrug ContaminationUncertaintyPharmaceutical Preparations

Stichwörter der Autor:innen

Analytical evaluation threshold (AET)ExtractablesLeachablesNumerical simulation benchmark (NSB)Relative response factor (RRF)Uncertainty factor (UF)

Substanzen

Pharmaceutical Preparations

Autor:innen und Institutionen

  • Department of Extractables & Leachables and Packaging Testing, Eurofins BPT, Via Buozzi 2, 20055, Vimodrone, MI, Italy.
  • Department of Extractables & Leachables and Packaging Testing, Eurofins BPT, Via Buozzi 2, 20055, Vimodrone, MI, Italy. simone.carrara@bpt.eurofinseu.com.

Zitieren

APA

Rozio, M. G., Angelini, D., & Carrara, S. (2025). Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-05946-5

Vancouver

Rozio MG, Angelini D, Carrara S. Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-05946-5

BibTeX
@article{Rozio2025,
  author = {Rozio, Marco Giulio and Angelini, Davide and Carrara, Simone},
  title = {Uncertainty factors and relative response factors: correcting detection and quantitation bias in extractables and leachables studies},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  doi = {10.1007/s00216-025-05946-5}
}
Kostenlos starten →