Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen
Analytical and Bioanalytical Chemistry · 2025
DOI: 10.1007/s00216-025-05885-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Stephen C Zambrzycki und 2 weiteren Autor:innen. Beteiligte Einrichtung: Bioanalytical Mass Spectrometry Group, Biosciences Division, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN, 37831 - 6131, USA. Hauptthemen laut MEDLINE: Tamoxifen, Single-Cell Analysis, Metabolomics, Mass Spectrometry. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 57 Literaturangaben. Gefördert von: NIGMS NIH HHS, Oak Ridge National Laboratory, National Institute of General Medical Sciences.
Abstract (Originalsprache)
Single-cell mass spectrometry (MS) is advancing our understanding of metabolic pathways in heterogeneous cell populations; however, many techniques are slow or require disruptive sample preparations. This study evaluated coupling a modified HP D100 single-cell inkjet dispenser with liquid vortex capture-mass spectrometry (D100/LVC-MS). The D100 is a single-cell inkjet dispenser capable of titrating solutions and isolating single cells via disposable cassettes equipped with microfluidic channels and an impedance sensor. The LVC-MS enables high-throughput capture, lysis, and ionization of analytes for mass spectrometric analysis. The D100/LVC-MS system was characterized through titration and single-cell experiments. Propranolol titration demonstrated linearity across a broad concentration range using the D100/LVC-MS system. Additionally, Hep G2 hepatocarcinoma cells and Chlamydomonas reinhardtii algae were used to showcase the D100's high-throughput or low-buffer-volume single-cell dispensing strategies. The D100/LVC-MS system's performance was validated by evaluating tamoxifen-induced steatosis in Hep G2 cells. Tamoxifen, associated with nonalcoholic fatty liver disease in breast cancer patients following long-term use, was tested in Hep G2 cells at 20 µM for 72 h against DMSO-treated controls. High-throughput analysis of 500 cells per condition, completed in 25 min per run, demonstrated the system's efficiency. The D100/LVC-MS system simultaneously quantified tamoxifen and measured triglycerides and phosphatidylcholines. Triglycerides were upregulated in the tamoxifen-treated cells and the results indicated two distinct cell populations, differing in tamoxifen and phosphatidylcholines levels, suggesting heterogeneity within the treated population. These findings highlight the D100/LVC-MS system as a cost-effective, high-throughput platform for single-cell metabolomics and lipidomics, with significant potential for evaluating metabolic alterations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Bioanalytical Mass Spectrometry Group, Biosciences Division, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN, 37831 - 6131, USA.
- Bioanalytical Mass Spectrometry Group, Biosciences Division, Oak Ridge National Laboratory, 1 Bethel Valley Rd, Oak Ridge, TN, 37831 - 6131, USA. cahilljf@ornl.gov.
Förderung
- NIGMS NIH HHS
- Oak Ridge National Laboratory
- National Institute of General Medical Sciences
Zitieren
APA
Zambrzycki, S. C., Kertesz, V., & Cahill, J. F. (2025). Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-05885-1
Vancouver
Zambrzycki SC, Kertesz V, Cahill JF. Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-05885-1
BibTeX
@article{Zambrzycki2025,
author = {Zambrzycki, Stephen C and Kertesz, Vilmos and Cahill, John F},
title = {Evaluating inkjet dispenser/liquid vortex capture-mass spectrometry for single-cell metabolomics in Hep G2 steatosis caused by tamoxifen},
journal = {Analytical and Bioanalytical Chemistry},
year = {2025},
doi = {10.1007/s00216-025-05885-1}
}
EUVIMED