EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Species-specific optimization of oxylipin ionization in LC–MS: a design of experiments approach to improve sensitivity

Louis Schmidt, Ulrike Garscha

Analytical and Bioanalytical Chemistry · 2025

DOI: 10.1007/s00216-025-05759-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Louis Schmidt und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical/Medicinal Chemistry, Institute of Pharmacy, Greifswald University, 17489, Greifswald, Germany. Hauptthemen laut MEDLINE: Oxylipins, Tandem Mass Spectrometry, Spectrometry, Mass, Electrospray Ionization. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität Greifswald.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Oxylipins are diverse bioactive signaling molecules, which occur in very low concentrations in complex matrices, posing challenges in achieving consistent and sensitive analysis. UHPLC-MS/MS is the preferred technique to separate and quantify these molecules, often optimized using a time-consuming trial-and-error approach. In this study, we applied the design of experiments (DoE) approach to systematically investigate the ionization properties of multiple oxylipin species. Fractional factorial and central composite designs were employed to detect relevant instrument parameters and optimize signal intensity in ESI–MS/MS analysis. Response surface modeling revealed distinct ionization and fragmentation behaviors between polar and apolar oxylipins, driven by their responses to interface temperature and collision-induced dissociation (CID) gas pressure. Particularly, prostaglandins and lipoxins benefit from higher CID gas pressure and lower temperatures compared to the lipophilic HODEs and HETEs to achieve optimal intensity in multiple reaction monitoring analysis. While global source parameters were optimized, analyte-specific entrance/exit potentials and collision energies required individual adjustments. The final method was applied to analyze seven oxylipin classes including leukotrienes, prostaglandins, lipoxins, resolvins, HETEs, HODE S , and HoTrEs. Although improvements in lower limits of quantification were modest (< 1 pg on-column), signal-to-noise ratios increased two-fold for lipoxins and resolvins and three- to four-fold for leukotrienes and HETEs, enhancing detection at trace levels. This DoE-guided strategy provides a powerful tool to improve UHPLC-MS/MS analysis of oxylipins across various instrument vendors, guiding the way towards inter-laboratory comparability. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

OxylipinsTandem Mass SpectrometrySpectrometry, Mass, Electrospray IonizationChromatography, High Pressure LiquidSpecies SpecificityLimit of DetectionLiquid Chromatography-Mass Spectrometry

Stichwörter der Autor:innen

Design of experiments (DoE)LipidomicsMethod optimizationOxylipinsUHPLC-ESI–MS/MS

Substanzen

Oxylipins

Autor:innen und Institutionen

  • Department of Pharmaceutical/Medicinal Chemistry, Institute of Pharmacy, Greifswald University, 17489, Greifswald, Germany.
  • Department of Pharmaceutical/Medicinal Chemistry, Institute of Pharmacy, Greifswald University, 17489, Greifswald, Germany. ulrike.garscha@uni-greifswald.de.

Förderung

  • Universität Greifswald

Zitieren

APA

Schmidt, L., & Garscha, U. (2025). Species-specific optimization of oxylipin ionization in LC–MS: a design of experiments approach to improve sensitivity. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-025-05759-6

Vancouver

Schmidt L, Garscha U. Species-specific optimization of oxylipin ionization in LC–MS: a design of experiments approach to improve sensitivity. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-025-05759-6

BibTeX
@article{Schmidt2025,
  author = {Schmidt, Louis and Garscha, Ulrike},
  title = {Species-specific optimization of oxylipin ionization in LC–MS: a design of experiments approach to improve sensitivity},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  doi = {10.1007/s00216-025-05759-6}
}
Kostenlos starten →