EUVIMEDEUVIMED entdecken
Crossref

Implementation of the ISO 33405 requirements and production of a certified reference material for nitrofuran metabolites as incurred chicken muscle

Fernando Gustavo Marques Violante, Evelyn de Freitas Guimarães, Nathália Oliveira Cavalcanti Zúniga, Francisco Radler de Aquino Neto

Analytical and Bioanalytical Chemistry · 2025

DOI: 10.1007/s00216-024-05681-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2025. Verfasst von Fernando Gustavo Marques Violante und 3 weiteren Autor:innen. Beteiligte Einrichtung: Scientific Metrology and Technology Directorate (Dimci), Chemical Metrology Division (Dquim), National Institute of Metrology, Quality and Technology…. Hauptthemen laut MEDLINE: Nitrofurans, Muscles, Drug Residues, Veterinary Drugs. Die Arbeit nennt 20 Literaturangaben. Gefördert von: the Carlos Chagas Filho Research Support Foundation of the Rio de Janeiro State - FAPERJ, National Council for Scientific and Technological Development (CNPq), Carlos Chagas Filho Research Support Foundation of the Rio de Janeiro State - FAPERJ.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Certified reference materials (CRMs) contribute to the traceability of measurement results to recognized anchor points, ideally to the International System of Units (SI), and consequently, to their comparability and reliability. In the area of veterinary drugs' residues in foods of animal origin, the important role of CRMs must be highlighted, given the problems caused by trade restrictions in some countries. The results of studies concerning the certification of an incurred matrix certified reference material (IMCRM) for the mass fraction of nitrofuran metabolites in chicken muscles are presented in this work. A batch of IMCRM candidates was produced from chicken muscle samples containing the metabolites 3-amino-2-oxazolidinone (AOZ), 3-amino-5-morpholinomethyl-2-oxazolidinone (AMOZ), semicarbazide (SEM), and 1-aminohydantoin (AHD). All the statistical approaches for the homogeneity and stability assessments were based on the principles contained within ISO Guide 35 (current ISO 33405:2024). All the quantitative analyses of the nitrofuran metabolites were performed by means of high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The properties studied were sufficiently homogeneous and stable at -20 °C for 360 days (the defined storage conditions). Under transport conditions, the AOZ metabolite showed instability at 50 °C. The residual moisture content was also monitored and showed instability at 20 °C and 50 °C. The characterization was performed via an exact matching calibration approach and the assigned values with their respective expanded uncertainties (k = 2) were 5.40 ± 1.2 ng g-1, 5.49 ± 0.85 ng g-1, 5.08 ± 1.2 ng g-1, and 6.01 ± 0.85 ng g-1 for the metabolites AOZ, AMOZ, AHD, and SEM, respectively, in the lyophilized chicken muscle. These values ranged from 1.3 to 1.5 ng g-1 on a wet basis. The expiration date for the CRM was estimated based on the stated limits for future values calculated from the confidence interval of the stability study's linear regression curve.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NitrofuransMusclesDrug ResiduesVeterinary DrugsAnimalsChickensTandem Mass SpectrometryReference StandardsChromatography, High Pressure LiquidReproducibility of ResultsOxazolidinones

Stichwörter der Autor:innen

Food safetyLiquid chromatography-tandem mass spectrometryMatrix reference materialsNitrofuran metabolites

Substanzen

NitrofuransOxazolidinonesVeterinary Drugs

Autor:innen und Institutionen

  • Scientific Metrology and Technology Directorate (Dimci), Chemical Metrology Division (Dquim), National Institute of Metrology, Quality and Technology (Inmetro), Duque de Caxias, RJ, Brazil. fmviolante@inmetro.gov.br.
  • Scientific Metrology and Technology Directorate (Dimci), Chemical Metrology Division (Dquim), National Institute of Metrology, Quality and Technology (Inmetro), Duque de Caxias, RJ, Brazil.
  • Chemistry Institute (IQ), Laboratory for the Support of Technological Development (Ladetec), Federal University of Rio de Janeiro (UFRJ), Rio de Janeiro, RJ, Brazil.

Förderung

  • the Carlos Chagas Filho Research Support Foundation of the Rio de Janeiro State - FAPERJ
  • National Council for Scientific and Technological Development (CNPq)
  • Carlos Chagas Filho Research Support Foundation of the Rio de Janeiro State - FAPERJ

Zitieren

APA

Violante, F. G. M., de Freitas Guimarães, E., Zúniga, N. O. C., & de Aquino Neto, F. R. (2025). Implementation of the ISO 33405 requirements and production of a certified reference material for nitrofuran metabolites as incurred chicken muscle. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05681-3

Vancouver

Violante FGM, de Freitas Guimarães E, Zúniga NOC, de Aquino Neto FR. Implementation of the ISO 33405 requirements and production of a certified reference material for nitrofuran metabolites as incurred chicken muscle. Analytical and Bioanalytical Chemistry. 2025. doi:10.1007/s00216-024-05681-3

BibTeX
@article{Violante2025,
  author = {Violante, Fernando Gustavo Marques and de Freitas Guimarães, Evelyn and Zúniga, Nathália Oliveira Cavalcanti and de Aquino Neto, Francisco Radler},
  title = {Implementation of the ISO 33405 requirements and production of a certified reference material for nitrofuran metabolites as incurred chicken muscle},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  doi = {10.1007/s00216-024-05681-3}
}
Kostenlos starten →