Preparation and application of multiple particle binding-liposomes for electrochemiluminescent signal amplification in bioassays
Analytical and Bioanalytical Chemistry · 2024
DOI: 10.1007/s00216-024-05532-1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Aki Tanaka und 2 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Analytical Chemistry, Kyoto Pharmaceutical University, 5 Misasaginakauchi-cho, Yamashina-ku, Kyoto, 607-8414, Japan. Hauptthemen laut MEDLINE: Liposomes, Luminescent Measurements, Electrochemical Techniques. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
In this study, multiple particle binding-liposomes (MPB-Lips), encapsulating the luminophore tris(2',2-bipyridyl)ruthenium (II) complex ([Ru(bpy)3]2+), were developed as an electrochemiluminescence (ECL) signal amplifier and were applied to detect the model analyte streptavidin (SA) using the indirect competitive ECL method. The MPB-Lips were prepared by mixing various ratios of two different liposomes-one containing a phospholipid with a primary amine group and a biotinyl group (BIO/NH2-Lip) and one containing a phospholipid with an N-hydroxysuccinimide group (NHS-Lip) to allow binding between particles via amide bonds. Quartz crystal microbalance analysis using SA-modified gold-coated quartz crystals showed that the frequency shift values of MPB-Lips gradually decreased in the order BIO/NH2-Lip:NHS-Lip = 1:0 < 1:1 < 1:3 < 1:5. This indicated that MPB-Lips were successfully formed. The indirect competitive ECL method using SA-modified gold electrodes showed that the 1:5-Lip system had greater sensitivity than the 1:0-Lip system-the limit of detection and quantification values for the systems were 1.84 and 6.30 μg mL-1 for 1:0-Lip, and 1.20 and 1.74 μg mL-1 for 1:5-Lip. Finally, the recovery of SA spiked in fetal bovine serum samples using the 1:5-Lip system showed good accuracy and precision with a recovery rate of 83-106% and relative standard deviation of 4-14%. Our study demonstrated that the MPB-Lips system was an effective and useful ECL amplifier and the ECL method using MPB-Lips could be applied to detect an analyte in a real sample.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Laboratory of Analytical Chemistry, Kyoto Pharmaceutical University, 5 Misasaginakauchi-cho, Yamashina-ku, Kyoto, 607-8414, Japan.
- Laboratory of Analytical Chemistry, Kyoto Pharmaceutical University, 5 Misasaginakauchi-cho, Yamashina-ku, Kyoto, 607-8414, Japan. takegami@mb.kyoto-phu.ac.jp.
Zitieren
APA
Tanaka, A., Konishi, A., & Takegami, S. (2024). Preparation and application of multiple particle binding-liposomes for electrochemiluminescent signal amplification in bioassays. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05532-1
Vancouver
Tanaka A, Konishi A, Takegami S. Preparation and application of multiple particle binding-liposomes for electrochemiluminescent signal amplification in bioassays. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05532-1
BibTeX
@article{Tanaka2024,
author = {Tanaka, Aki and Konishi, Atsuko and Takegami, Shigehiko},
title = {Preparation and application of multiple particle binding-liposomes for electrochemiluminescent signal amplification in bioassays},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-024-05532-1}
}
EUVIMED