EUVIMEDEUVIMED entdecken
Crossref

An acidless microwave-assisted wet digestion of biological samples as a greener alternative: applications from COVID-19 monitoring to plant nanobiotechnology

Ana Beatriz Santos da Silva, Ketolly Natanne da Silva Leal, Marco Aurélio Zezzi Arruda

Analytical and Bioanalytical Chemistry · 2025-03 · 417 (7) · 1271-1282

DOI: 10.1007/s00216-024-05472-w ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 21.08.2024. Verfasst von Ana Beatriz Santos da Silva und 2 weiteren Autor:innen. Beteiligte Einrichtung: Spectrometry, Sample Preparation and Mechanization Group, Institute of Chemistry, University of Campinas - Unicamp, P.O. Box 6154, Campinas, SP, 1308…. Hauptthemen laut MEDLINE: Microwaves, COVID-19. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Fundação de Amparo à Pesquisa do Estado de São Paulo.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Sample preparation in an analytical sequence increases the number of errors, is highly time-consuming, and involves the manipulation of hazardous reagents. Therefore, when an improvement in an analytical method is required, the sample preparation step needs to be optimised or redesigned. Moreover, this step can involve significant toxic reagents and a high volume of waste. In that regard, this study proposes a new procedure based on microwave-assisted wet digestion combining two green strategies: a miniaturised system (with a few microlitres of volume) and the only use of hydrogen peroxide. Three biological samples (human serum, urine, and plant in vitro material) were chosen due to their high potential for disease monitoring, toxicological studies, and biotechnology applications. Several trace elements (Ca, Cd, Co, Cu, Fe, Mg, Mn, Mo, Ni, Se, and Zn) were determined by inductively coupled plasma optical emission spectroscopy and inductively coupled plasma mass spectrometry. For human serum and urine, a certified reference material was used to check for accuracy; the recovery ranged from 72% (Cd, ICP-MS) to 105% (Mg, ICP OES) for serum, while for urine, they varied from 82% (Ni, ICP-MS) to 122% (Zn, ICP-MS). For the soybean callus sample (in vitro plant material), a comparison between the proposed method and the acid digestion method was conducted to evaluate the accuracy, and the results agreed. The detection limits were 0.001-60 µg L-1 (lowest for Cd), thus demonstrating a suitable sensitivity. Moreover, the decomposition efficiency was demonstrated by determining the residual carbon, and a low amount was found in the final product digested (below 0.8% w v-1). A green metric approach was calculated for the proposed method, and according to AGREEprep software, it was found to be around 0.4. Finally, the method was applied to urine samples collected in patients with COVID-19 and soybean callus cultivated with silver nanoparticles. This sample preparation method is a new acidless and miniaturised alternative for elemental analysis involving biological samples.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MicrowavesCOVID-19HumansTrace ElementsSARS-CoV-2BiotechnologyMass SpectrometryNanotechnologyGreen Chemistry TechnologyLimit of Detection

Stichwörter der Autor:innen

Biological samplesGreen methodHydrogen peroxideIn loco acid generationSample preparation

Substanzen

Trace Elements

Autor:innen und Institutionen

  • Spectrometry, Sample Preparation and Mechanization Group, Institute of Chemistry, University of Campinas - Unicamp, P.O. Box 6154, Campinas, SP, 13083-970, Brazil.
  • National Institute of Science and Technology for Bioanalytics, Institute of Chemistry, University of Campinas - Unicamp, P.O. Box 6154, Campinas, SP, 13083-970, Brazil.
  • Center of Environmental Studies, São Paulo State University, Rio Claro, 13506900, Brazil.
  • Spectrometry, Sample Preparation and Mechanization Group, Institute of Chemistry, University of Campinas - Unicamp, P.O. Box 6154, Campinas, SP, 13083-970, Brazil. zezzi@unicamp.br.
  • National Institute of Science and Technology for Bioanalytics, Institute of Chemistry, University of Campinas - Unicamp, P.O. Box 6154, Campinas, SP, 13083-970, Brazil. zezzi@unicamp.br.

Förderung

  • Conselho Nacional de Desenvolvimento Científico e Tecnológico
  • Fundação de Amparo à Pesquisa do Estado de São Paulo

Zitieren

APA

da Silva, A. B. S., da Silva Leal, K. N., & Arruda, M. A. Z. (2025). An acidless microwave-assisted wet digestion of biological samples as a greener alternative: applications from COVID-19 monitoring to plant nanobiotechnology. Analytical and Bioanalytical Chemistry, 417(7), 1271-1282. https://doi.org/10.1007/s00216-024-05472-w

Vancouver

da Silva ABS, da Silva Leal KN, Arruda MAZ. An acidless microwave-assisted wet digestion of biological samples as a greener alternative: applications from COVID-19 monitoring to plant nanobiotechnology. Analytical and Bioanalytical Chemistry. 2025;417(7):1271-1282. doi:10.1007/s00216-024-05472-w

BibTeX
@article{daSilva2025,
  author = {da Silva, Ana Beatriz Santos and da Silva Leal, Ketolly Natanne and Arruda, Marco Aurélio Zezzi},
  title = {An acidless microwave-assisted wet digestion of biological samples as a greener alternative: applications from COVID-19 monitoring to plant nanobiotechnology},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2025},
  volume = {417},
  number = {7},
  pages = {1271--1282},
  doi = {10.1007/s00216-024-05472-w}
}
Kostenlos starten →