Calibration transfer between NIR instruments using optimally predictive calibration subsets
Analytical and Bioanalytical Chemistry · 2024-10 · 416 (24) · 5351-5364
DOI: 10.1007/s00216-024-05468-6 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 03.08.2024. Verfasst von Jan P M Andries und 1 weiteren Autor:innen. Beteiligte Einrichtung: Research Group Analysis Techniques in the Life Sciences, Avans Hogeschool, University of Professional Education, P.O. Box 90116, 4800 RA, Breda, The …. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
In this study, a new approach for the selection of informative standardization samples from the original calibration set for the transfer of a calibration model between NIR instruments is proposed and evaluated. First, a calibration model is developed, after variable selection by the Final Complexity Adapted Models (FCAM) method, using the significance of the PLS regression coefficients (FCAM-SIG) as selection criterion. Then, the resulting model is used for the selection of the best fitting subset of calibration samples with optimally predictive ability, called the optimally predictive calibration subset (OPCS). Next, the standardization samples are selected from the OPCS. The spectra on the slave instruments are transferred to corresponding spectra on the master instrument by the widely used Piecewise Direct Standardization (PDS) method. Thereafter, for the test set on the slave instrument, a 3D response surface plot is drawn for the root mean squared error of prediction (RMSEP) as a function of the number of OPCS samples and window sizes used for the PDS method. Finally, the smallest set of calibration samples, in combination with the optimal window size, providing the optimal RMSEP, is selected as standardization set. The proposed OPCS approach for the selection of standardization samples is tested on two real-life NIR data sets providing 13 X-y combinations to model. The results show that the obtained numbers of OPCS-based standardization samples are statistically significantly lower than those obtained with the widely used representative sample selection method of Kennard and Stone, while the predictive performances are similar.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research Group Analysis Techniques in the Life Sciences, Avans Hogeschool, University of Professional Education, P.O. Box 90116, 4800 RA, Breda, The Netherlands. jp.andries@avans.nl.
- Department of Analytical Chemistry, Applied Chemometrics and Molecular Modelling, Vrije Universiteit Brussel-VUB, Laarbeeklaan 103, B-1090, Brussels, Belgium.
Zitieren
APA
Andries, J. P. M., & Vander Heyden, Y. (2024). Calibration transfer between NIR instruments using optimally predictive calibration subsets. Analytical and Bioanalytical Chemistry, 416(24), 5351-5364. https://doi.org/10.1007/s00216-024-05468-6
Vancouver
Andries JPM, Vander Heyden Y. Calibration transfer between NIR instruments using optimally predictive calibration subsets. Analytical and Bioanalytical Chemistry. 2024;416(24):5351-5364. doi:10.1007/s00216-024-05468-6
BibTeX
@article{Andries2024,
author = {Andries, Jan P M and Vander Heyden, Yvan},
title = {Calibration transfer between NIR instruments using optimally predictive calibration subsets},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
volume = {416},
number = {24},
pages = {5351--5364},
doi = {10.1007/s00216-024-05468-6}
}
EUVIMED