Development of a certified reference material for d-phenylalanine with evaluation of enantiomeric purity
Analytical and Bioanalytical Chemistry · 2024
DOI: 10.1007/s00216-024-05456-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Shiwen Luo und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China. Hauptthemen laut MEDLINE: Phenylalanine, Reference Standards. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 23 Literaturangaben. Gefördert von: National Institute of Metrology, P.R. China, Key R&D Plan of the Ministry of Science and Technology.
Abstract (Originalsprache)
D-Phenylalanine (D-Phe) is a small chiral organic molecule that is both an important pharmaceutical intermediate and used as a calibrator for quantifying amino acids in liquid chromatography-circular dichroism. We have developed a process for a national certified reference material (CRM) for D-Phe following ISO 17034:2016. The identity of D-Phe was confirmed using mass spectrometry (MS) and nuclear magnetic resonance (NMR), infrared, and ultraviolet (UV) spectroscopy. The absolute optical conformation was also determined using circular dichroism (CD) spectroscopy and optical rotation measurements. Impurities were identified via liquid chromatography (LC) with a UV-Vis detector and a charged aerosol detector (CAD) and LC-MS. Both mass balance and quantitative NMR were employed for value assessment, and the associated uncertainty was evaluated. The certified purity was determined to be 0.995 ± 0.003 g/g, a validation that was confirmed by CD using L-Phe CRM as a calibrator. Twenty milligrams of raw material was packed in sealed brown glass tubes for storage, and no inhomogeneity was observed. Stability tests revealed that the D-Phe CRM remained stable at -20 °C for at least 26 months, at 4 °C for at least 14 days, and at 25 °C and 60 °C for at least 7 days. The D-Phe CRM can be used to ensure the accuracy and reliability of D-Phe quantitation in the pharmaceutical field and also as a calibrator to ensure traceability to the International System of Units (SI) for L-Phe quantitation and protein purity analysis using LC-CD methods. The approach outlined in this paper also has potential for use in the development of other chiral CRMs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Center for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China.
- China National Accreditation Service for Conformity Assessment, Beijing, 100062, China.
- Center for Advanced Measurement Science, National Institute of Metrology, Beijing, 100029, China. wulq@nim.ac.cn.
Förderung
- National Institute of Metrology, P.R. China
- Key R&D Plan of the Ministry of Science and Technology
Zitieren
APA
Luo, S., Liu, Y., Wang, X., Wang, Z., Yang, B., Wang, J., & Wu, L. (2024). Development of a certified reference material for d-phenylalanine with evaluation of enantiomeric purity. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05456-w
Vancouver
Luo S, Liu Y, Wang X, Wang Z, Yang B, Wang J, et al. Development of a certified reference material for d-phenylalanine with evaluation of enantiomeric purity. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05456-w
BibTeX
@article{Luo2024,
author = {Luo, Shiwen and Liu, Yahui and Wang, Xianxia and Wang, Ziliang and Yang, Bin and Wang, Jing and Wu, Liqing},
title = {Development of a certified reference material for d-phenylalanine with evaluation of enantiomeric purity},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-024-05456-w}
}
EUVIMED