Quantifying non-transferrin-bound iron (NTBI) in human plasma: incorporating BODIPY-pyridylhydrazone (BODIPY-PH) within a thin green film linked to a portable fluorescence-based device
Analytical and Bioanalytical Chemistry · 2024
DOI: 10.1007/s00216-024-05441-3 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Puttaraksa Naksen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 3419…. Hauptthemen laut MEDLINE: Iron, Boron Compounds, Spectrometry, Fluorescence, Limit of Detection. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: The National Research Council of Thailand.
Abstract (Originalsprache)
Free iron in human serum or non-transferrin-bound iron (NTBI) can generate free radicals and lead to oxidative damage. Moreover, it is highly toxic to various tissues and a vital biomarker related to the iron-loading status of thalassemia and Alzheimer's patients. In NTBI in healthy individuals, NTBI levels are typically less than 1 µM; current NTBI analysis usually requires advanced instrumentation and many-step sample pretreatment. To address this issue, we employed our invented BODIPY derivative, BODIPY-PH, as a fluorescence probe and trapped it onto the microcentrifuge tube lid using tapioca starch. The fluorescence intensity of BODIPY-PH increased with increasing NTBI concentration (turn-on). The developed portable reaction chamber facilitates rapid analysis (∼5 min) using small sample volumes (10 μL sample in a total volume of 600 μL). Under optimum conditions, using the sample-developed portable fluorescence device and fluorescence spectrometer, we achieved impressive limits of detection (LOD) of 0.003 and 0.0015 μM, respectively. Furthermore, the developed sensors show relatively high selectivity toward Fe3+ over other metal ions and biomolecules (i.e., Fe2+, Cr3+, Cu2+, and glucose). The sensor performance in serum samples of thalassemia patients exhibited no significant difference compared to the labeled value (obtained from standard methods). Overall, the developed fluorescence sensor is suitable for determining NTBI and offers high sensitivity, high selectivity, and a short incubation time (5 min). Moreover, the method requires a limited number of reagents, is simple to use, and uses low-cost equipment to determine NTBI in human serum samples.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
- Nanomaterials Science, Sensors & Catalysis for Problem-Based Projects, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
- National Nanotechnology Center, National Science and Technology Development Agency, Thailand Science Park, Pathum Thani, 12120, Thailand.
- Center for Organic Electronic and Alternative Energy, Department of Chemistry and Center for Innovation in Chemistry, Faculty of Science, Ubon Ratchathani University, Warinchumrap, Ubon Ratchathani, 34190, Thailand.
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai, 50000, Thailand.
- Department of Physics, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, 34190, Thailand.
Förderung
- The National Research Council of Thailand
Zitieren
APA
Naksen, P., Chansaenpak, K., Jungsuttiwong, S., Intayot, R., Jakmunee, J., Pencharee, S., Lieberzeit, P., & Jarujamrus, P. (2024). Quantifying non-transferrin-bound iron (NTBI) in human plasma: incorporating BODIPY-pyridylhydrazone (BODIPY-PH) within a thin green film linked to a portable fluorescence-based device. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05441-3
Vancouver
Naksen P, Chansaenpak K, Jungsuttiwong S, Intayot R, Jakmunee J, Pencharee S, et al. Quantifying non-transferrin-bound iron (NTBI) in human plasma: incorporating BODIPY-pyridylhydrazone (BODIPY-PH) within a thin green film linked to a portable fluorescence-based device. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05441-3
BibTeX
@article{Naksen2024,
author = {Naksen, Puttaraksa and Chansaenpak, Kantapat and Jungsuttiwong, Siriporn and Intayot, Ratchadaree and Jakmunee, Jaroon and Pencharee, Somkid and Lieberzeit, Peter and Jarujamrus, Purim},
title = {Quantifying non-transferrin-bound iron (NTBI) in human plasma: incorporating BODIPY-pyridylhydrazone (BODIPY-PH) within a thin green film linked to a portable fluorescence-based device},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-024-05441-3}
}
EUVIMED