A flexible glucose biosensor modified by reduced-swelling and conductive zwitterionic hydrogel enzyme membrane
Analytical and Bioanalytical Chemistry · 2024
DOI: 10.1007/s00216-024-05429-z ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Chengcheng Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Glucose Oxidase, Enzymes, Immobilized, Glucose. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, 111 Project of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
This paper reports a flexible glucose biosensor which is modified by a reduced-swelling and conductive zwitterionic hydrogel enzyme membrane that contains two forms of chemical cross-links. One chemical cross-linking is induced by thermal initiators and forms the basal network of the hydrogel. Another cross-linking is achieved by the coordination interactions between the multivalent metal ion Al3+ and anionic group -COO- of zwitterionic poly-carboxy betaine (pCBMA), which significantly increase the cross-linking density of the zwitterionic hydrogel, improving the reduced-swelling property and reducing the pore size. The better reduced-swelling property and reduced diameters of pores within the zwitterionic hydrogel make less glucose oxidase (GOx) leakage, thus significantly improving the enzyme membrane's service life. By introducing the Al3+ and Cl-, the conductivity of the zwitterionic hydrogel is enhanced approximately 10.4-fold. According to the enhanced conductivity, the reduced-swelling property, and the high GOx loading capacity of the zwitterionic hydrogel, the sensitivity of the biosensor with GOx/pCBMA-Al3+ is significantly improved by 5 times and has a long service life. Finally, the proposed GOx/pCBMA-Al3+ biosensor was applied in non-invasive blood glucose detection on the human body, verifying the capability in practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, China.
- School of Future Technologies, Tianjin University, Tianjin, 300072, China.
- State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, 92 Weijin Road, Nankai District, Tianjin, 300072, China. puzhihua@tju.edu.cn.
Förderung
- National Natural Science Foundation of China
- 111 Project of China
- National Key Research and Development Program of China
Zitieren
APA
Li, C., Zhu, W., Ma, Y., Zheng, H., Zhang, X., Li, D., & Pu, Z. (2024). A flexible glucose biosensor modified by reduced-swelling and conductive zwitterionic hydrogel enzyme membrane. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05429-z
Vancouver
Li C, Zhu W, Ma Y, Zheng H, Zhang X, Li D, et al. A flexible glucose biosensor modified by reduced-swelling and conductive zwitterionic hydrogel enzyme membrane. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05429-z
BibTeX
@article{Li2024,
author = {Li, Chengcheng and Zhu, Wangwang and Ma, Yuxiao and Zheng, Hao and Zhang, Xingguo and Li, Dachao and Pu, Zhihua},
title = {A flexible glucose biosensor modified by reduced-swelling and conductive zwitterionic hydrogel enzyme membrane},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
doi = {10.1007/s00216-024-05429-z}
}
EUVIMED