Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Hirobumi Sunayama und 3 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Engineering, Kobe University, 1-1, Rokkodai-Cho, Nada-Ku, Kobe, 657-8501, Japan. sunayama@penguin.kobe-u.ac.jp. Hauptthemen laut MEDLINE: Glycated Serum Albumin, Serum Albumin, Glycation End Products, Advanced, Limit of Detection. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Dynamic Alliance for Open Innovation Bridging Human, Environment and Materials” offered by Network Joint Research Center for Materials and Devices, Kobe University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantifying glycated albumin (GA) levels in the blood is crucial for diagnosing diabetes because they strongly correlate with blood glucose concentration. In this study, a biotic/abiotic sandwich assay was developed for the facile, rapid, and susceptible detection of human serum albumin (HSA) and GA. The proposed sandwich detection system was assembled using a combination of two synthetic polymer receptors and natural antibodies. Molecularly imprinted polymer nanogels (MIP-NGs) for HSA (HSA-MIP-NGs) were used to mimic capture antibodies, whereas antibodies for HSA or GA were used as primary antibodies and fluorescent signaling MIP-NGs for the Fc domain of IgG (F-Fc-MIP-NGs) were used as a secondary antibody mimic to indicate the binding events. The HSA/anti-HSA/F-Fc-MIP-NGs complex, formed by incubating HSA and anti-HSA antibodies with F-Fc-MIP-NGs, was captured by HSA-MIP-NGs immobilized on the chips for fluorescence measurements. The analysis time was less than 30 min, and the limit of detection was 15 pM. After changing the anti-HSA to anti-GA (monoclonal antibody), the fluorescence response toward GA exceeded that of HSA, indicating successful GA detection using the proposed sandwich detection system. Therefore, the proposed system could change the detection property by changing a primary antibody, indicating that this system can be applied to various target proteins and, especially, be a powerful approach for facile and rapid analysis methods for proteins with structural similarity. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Glycated Serum AlbuminSerum AlbuminGlycation End Products, AdvancedLimit of DetectionHumansSerum Albumin, HumanSpectrometry, FluorescenceMolecularly Imprinted PolymersNanogels

Stichwörter der Autor:innen

Abiotic/biotic sandwich detection systemDiabetesGlycated albuminMolecularly imprinted polymersPost-imprinting modification

Substanzen

Glycated Serum AlbuminSerum AlbuminGlycation End Products, AdvancedSerum Albumin, HumanMolecularly Imprinted PolymersNanogels

Autor:innen und Institutionen

  • Graduate School of Engineering, Kobe University, 1-1, Rokkodai-Cho, Nada-Ku, Kobe, 657-8501, Japan. sunayama@penguin.kobe-u.ac.jp.
  • Graduate School of Engineering, Kobe University, 1-1, Rokkodai-Cho, Nada-Ku, Kobe, 657-8501, Japan.
  • Department of Chemistry, Faculty of Science and Technology, Rajamangala University of Technology Thanyaburi, Klong Luang, Khlong Hok, 12110, Pathum Thani, Thailand.
  • TearExo Inc., 1-1, Rokkodai-Cho, Nada-Ku, Kobe, 657-8501, Japan.
  • Innovation and Commercialization Division, Kobe University, 1-1, Rokkodai-Cho, Nada-Ku, Kobe, 657-8501, Japan. takeuchi@gold.kobe-u.ac.jp.
  • Center for Advanced Medical Engineering Research & Development (CAMED), Kobe University, 1-5-1, Minatojima-minamimachi, Chuo-Ku, Kobe, 650-0047, Japan. takeuchi@gold.kobe-u.ac.jp.

Förderung

  • Japan Society for the Promotion of Science
  • Dynamic Alliance for Open Innovation Bridging Human, Environment and Materials” offered by Network Joint Research Center for Materials and Devices
  • Kobe University

Zitieren

APA

Sunayama, H., Cheubong, C., Takano, E., & Takeuchi, T. (2024). Facile biotic/abiotic sandwich detection system for the highly sensitive detection of human serum albumin and glycated albumin. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05403-9

Vancouver

Sunayama H, Cheubong C, Takano E, Takeuchi T. Facile biotic/abiotic sandwich detection system for the highly sensitive detection of human serum albumin and glycated albumin. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05403-9

BibTeX
@article{Sunayama2024,
  author = {Sunayama, Hirobumi and Cheubong, Chehasan and Takano, Eri and Takeuchi, Toshifumi},
  title = {Facile biotic/abiotic sandwich detection system for the highly sensitive detection of human serum albumin and glycated albumin},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  doi = {10.1007/s00216-024-05403-9}
}
Kostenlos starten →