EUVIMEDEUVIMED entdecken
Crossref

Biomonitoring urinary organophosphorus flame retardant metabolites by liquid–liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry and their association with oxidative stress

Yongxian Li, Yingyi Dai, Xinni Luo, Lin Zhang, Jun Yuan, Lei Tan

Analytical and Bioanalytical Chemistry · 2024

DOI: 10.1007/s00216-024-05393-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Yongxian Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Guangzhou Center for Disease Control and Prevention, Guangzhou, 510440, China. Hauptthemen laut MEDLINE: Flame Retardants, Tandem Mass Spectrometry, Oxidative Stress, Biological Monitoring. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Organophosphate flame retardants (OPFRs) are widely used as substitutes for traditional brominated flame retardants, necessitating a reliable and sensitive method for biomonitoring their urinary metabolites to assess human exposure. This study conducted biomonitoring of 10 metabolites of OPFRs in 152 adults and assessed their association with oxidative stress biomarkers 8-hydroxydeoxyguanosine and 8-hydroxyguanosine. Urinary metabolites of OPFRs were released via enzymatic deconjugation. The addition of sodium chloride to the urine samples increases the ionic strength, inducing a salting-out effect that reduces the solubility of these compounds, thereby facilitating their extraction with a mixture of ethyl acetate and acetonitrile. Then, the metabolites of OPFRs were quantified by ultra-high performance liquid chromatography-tandem mass spectrometry, and we validated the method for linear range, precision, matrix effect, and method detection limit. The detection limit of the metabolites of OPFRs ranged from 0.01 to 0.2 μg/L, and these metabolites were detected with high frequencies ranging from 25.0 to 98.68% in the urine samples. The concentration of bis (2-chloroethyl) phosphate was significantly higher in males than in females, with the geometric mean concentration of 0.88 μg/L for males and 0.53 μg/L for females, respectively. Spearman correlation analysis revealed weak but statistically significant positive correlations among the urinary metabolites. Bayesian kernel machine regression analysis showed a significant positive association between elevated urinary concentrations of metabolites of OPFRs and increased oxidative stress levels. Di-n-butyl phosphate was identified as the metabolite that significantly contributed to the elevated level of 8-hydroxyguanosine.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Flame RetardantsTandem Mass SpectrometryOxidative StressBiological MonitoringOrganophosphorus CompoundsLiquid-Liquid ExtractionLimit of DetectionHumansFemaleMaleChromatography, High Pressure LiquidAdultMiddle AgedBiomarkersYoung Adult

Stichwörter der Autor:innen

Human biomonitoringLiquid–liquid extractionOrganophosphate flame retardantsOxidative stressUltra-high performance liquid chromatography-tandem mass spectrometry

Substanzen

Flame RetardantsOrganophosphorus CompoundsBiomarkers

Autor:innen und Institutionen

  • Guangzhou Center for Disease Control and Prevention, Guangzhou, 510440, China.
  • School of Public Health, Southern Medical University, Guangzhou, 510515, China.
  • Affiliated Brain Hospital of Guangzhou Medical University, Guangzhou, 510370, China.
  • Guangzhou Center for Disease Control and Prevention, Guangzhou, 510440, China. jsutanlei@gmail.com.
  • School of Public Health, Southern Medical University, Guangzhou, 510515, China. jsutanlei@gmail.com.

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Li, Y., Dai, Y., Luo, X., Zhang, L., Yuan, J., & Tan, L. (2024). Biomonitoring urinary organophosphorus flame retardant metabolites by liquid–liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry and their association with oxidative stress. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05393-8

Vancouver

Li Y, Dai Y, Luo X, Zhang L, Yuan J, Tan L. Biomonitoring urinary organophosphorus flame retardant metabolites by liquid–liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry and their association with oxidative stress. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05393-8

BibTeX
@article{Li2024,
  author = {Li, Yongxian and Dai, Yingyi and Luo, Xinni and Zhang, Lin and Yuan, Jun and Tan, Lei},
  title = {Biomonitoring urinary organophosphorus flame retardant metabolites by liquid–liquid extraction and ultra-high performance liquid chromatography-tandem mass spectrometry and their association with oxidative stress},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  doi = {10.1007/s00216-024-05393-8}
}
Kostenlos starten →