Nanozyme catalysis pressure-powered intuitive distance variation for portable quantitative detection of H2S with the naked eye

Xuan Hu, Huifang Zhang, Xinyu Guo, Zhen Wang, Qitong Huang, Yu Wang, Xiaoming Ma, Zhenyu Lin

Analytical and Bioanalytical Chemistry · 2024

DOI: 10.1007/s00216-024-05390-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Xuan Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, China. Hauptthemen laut MEDLINE: Hydrogen Sulfide, Limit of Detection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Natural Science Foundation of Jiangxi Province, National Natural Science Foundation of China, National College Students Innovation and Entrepreneurship Training Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As a representative gas of food spoilage, the development of rapid hydrogen sulfide (H2S) analysis strategies for food safety control is in great demand. Despite traditional methods for H2S detection possessing great achievements, they are still incapable of meeting the requirement of portability and quantitative detection at the same time. Herein, a nanozyme catalysis pressure-powered sensing platform that enables visual quantification with the naked eye is proposed. In this methodology, Pt nanozyme inherits the catalase-like activity to facilitate the decomposition of H2O2 to O2, which can significantly improve the pressure in the closed container, further pushing the movement of indicator dye. Furthermore, H2S was found to effectively inhibit the catalytic activity of Pt nanozyme, indicating that the catalase-like activity of PtNPs may be regulated by varying concentrations of H2S. Therefore, by utilizing a self-designed pressure-powered microchannel device, the concentration of H2S was successfully converted into a distinct signal variation in distance. The effectiveness of the as-designed sensor in assessing the spoilage of red wine by H2S determination has been demonstrated. It exhibits a strong correlation between the change in dye distance and H2S concentration within the range of 1-250 μM, with a detection limit of 0.17 μM. This method is advantageous as it enhances the quantitative detection of H2S with the naked eye based on the portable pressure-powered sensing platform, as compared to traditional H2S biosensors. Such a pressure-powered distance variation platform would greatly broaden the application of H2S-based detection in food spoilage management.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hydrogen SulfideLimit of DetectionCatalysisWinePlatinumHydrogen PeroxidePressureMetal NanoparticlesBiosensing TechniquesFood Analysis

Stichwörter der Autor:innen

BiosensorsDistance variationFood spoilageH2SNanozymePt nanoparticle

Substanzen

Hydrogen SulfidePlatinumHydrogen Peroxide

Autor:innen und Institutionen

  • School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, China.
  • Department of Chemistry, Nanchang University, Nanchang, 330031, China.
  • Key Laboratory of Biomedical Sensors of Ganzhou, Key Laboratory of Tissue Engineering of Jiangxi Province, Gannan Medical University, Ganzhou, 341000, China.
  • School of Chemistry and Chemical Engineering, Gannan Normal University, Ganzhou, 341000, China. maxlovery@163.com.
  • MOE Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, 350116, China…

Förderung

  • Natural Science Foundation of Jiangxi Province
  • National Natural Science Foundation of China
  • National College Students Innovation and Entrepreneurship Training Program

Zitieren

APA

Hu, X., Zhang, H., Guo, X., Wang, Z., Huang, Q., Wang, Y., Ma, X., & Lin, Z. (2024). Nanozyme catalysis pressure-powered intuitive distance variation for portable quantitative detection of H2S with the naked eye. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05390-x

Vancouver

Hu X, Zhang H, Guo X, Wang Z, Huang Q, Wang Y, et al. Nanozyme catalysis pressure-powered intuitive distance variation for portable quantitative detection of H2S with the naked eye. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05390-x

BibTeX
@article{Hu2024,
  author = {Hu, Xuan and Zhang, Huifang and Guo, Xinyu and Wang, Zhen and Huang, Qitong and Wang, Yu and Ma, Xiaoming and Lin, Zhenyu},
  title = {Nanozyme catalysis pressure-powered intuitive distance variation for portable quantitative detection of H2S with the naked eye},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  doi = {10.1007/s00216-024-05390-x}
}
Kostenlos starten →