EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Simultaneous quantification of terpenes and cannabinoids by reversed-phase LC-APCI-MS/MS in Cannabis sativa L. samples combined with a subsequent chemometric analysis

Justine Raeber, Michael Poetzsch, Anina Schmidli, Sina Favrod, Christian Steuer

Analytical and Bioanalytical Chemistry · 2024

DOI: 10.1007/s00216-024-05349-y ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift Analytical and Bioanalytical Chemistry, 2024. Verfasst von Justine Raeber und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Pharmaceutical Sciences, ETH Zurich, Vladimir-Prelog-Weg 1-5/10, CH-8093, Zurich, Switzerland. Hauptthemen laut MEDLINE: Cannabis, Cannabinoids, Tandem Mass Spectrometry, Terpenes. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss Federal Institute of Technology Zurich.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cannabis sativa L . has been the most discussed medicinal plant in recent years. In particular, the dynamic shift from a formerly illicit and tightly controlled substance to a plant recognized for both medicinal and recreational purposes has brought C. sativa into the global spotlight. Due to the ongoing international legalization processes, fast and convenient analytical methods for the quality control of C. sativa flowers for medicinal and recreational purposes are of tremendous interest. In this study, we report the development and validation of a liquid chromatography-tandem mass spectrometry (LC–MS/MS)-based method applying atmospheric pressure chemical ionization (APCI) to fully quantify 16 terpenes and 7 cannabinoids including their acidic forms by a single chromatographic method. The method presented here is unique and simple, as it eliminates the need for derivatization reactions and includes the unconventional analysis of volatile compounds by liquid chromatography. Samples were prepared by a simple and fast ethanolic extraction. Separation was accomplished within 25 min on a reversed-phase C18 column. Method validation was conducted according to international guidelines regarding selectivity, accuracy, precision, robustness, and linearity. Detection was done in multiple reaction monitoring, which allowed the simultaneous quantification of co-eluting analytes applying two selective mass transitions. In addition, due to reproducible in-source decarboxylation, the acidic forms of cannabinoids were reliably quantified using mass transitions of the neutral forms. The accuracy given as the bias was below 15% for all analytes. Matrix effects for cannabinoids were studied by spiking Humulus lupulus extracts with the analytes at varying concentrations. APCI did not show susceptibility toward ion suppression or enhancement. In addition, the recovery effect after spiking was between 80 and 120% for terpenes. Further, 55 authentic C. sativa extracts were fully quantified, and the obtained results for the terpene profiles were compared to state-of-the-art gas chromatography coupled to flame ionization detection. Comparable results were achieved, emphasizing the method’s applicability for cannabinoids and terpenes. Further, acquired metabolite patterns for C. sativa samples were studied, identifying a relationship between cannabinoid and terpene patterns, as well as the abundance of myrcene in CBD-dominant C. sativa strains. Graphical Abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CannabisCannabinoidsTandem Mass SpectrometryTerpenesLimit of DetectionChromatography, Reverse-PhaseReproducibility of ResultsPlant ExtractsAtmospheric Pressure

Stichwörter der Autor:innen

APCICannabinoidsHPLCMass spectrometryTerpenes

Substanzen

CannabinoidsTerpenesPlant Extracts

Autor:innen und Institutionen

  • Institute of Pharmaceutical Sciences, ETH Zurich, Vladimir-Prelog-Weg 1-5/10, CH-8093, Zurich, Switzerland.
  • Swiss Drug Testing GmbH, Technoparkstrasse 2, CH-8406, Winterthur, Switzerland.
  • Institute of Pharmaceutical Sciences, ETH Zurich, Vladimir-Prelog-Weg 1-5/10, CH-8093, Zurich, Switzerland. christian.steuer@pharma.ethz.ch.

Förderung

  • Swiss Federal Institute of Technology Zurich

Zitieren

APA

Raeber, J., Poetzsch, M., Schmidli, A., Favrod, S., & Steuer, C. (2024). Simultaneous quantification of terpenes and cannabinoids by reversed-phase LC-APCI-MS/MS in Cannabis sativa L. samples combined with a subsequent chemometric analysis. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-024-05349-y

Vancouver

Raeber J, Poetzsch M, Schmidli A, Favrod S, Steuer C. Simultaneous quantification of terpenes and cannabinoids by reversed-phase LC-APCI-MS/MS in Cannabis sativa L. samples combined with a subsequent chemometric analysis. Analytical and Bioanalytical Chemistry. 2024. doi:10.1007/s00216-024-05349-y

BibTeX
@article{Raeber2024,
  author = {Raeber, Justine and Poetzsch, Michael and Schmidli, Anina and Favrod, Sina and Steuer, Christian},
  title = {Simultaneous quantification of terpenes and cannabinoids by reversed-phase LC-APCI-MS/MS in Cannabis sativa L. samples combined with a subsequent chemometric analysis},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  doi = {10.1007/s00216-024-05349-y}
}
Kostenlos starten →