Generation of macro- and microplastic databases by high-throughput FTIR analysis with microplate readers
Analytical and Bioanalytical Chemistry · 2024-03 · 416 (6) · 1311-1320
DOI: 10.1007/s00216-024-05127-w ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 13.01.2024. Verfasst von Win Cowger und 7 weiteren Autor:innen. Beteiligte Einrichtung: Moore Institute for Plastic Pollution Research, Long Beach, CA, USA. wincowger@gmail.com. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Renewable Energy Laboratory, Possibility Lab, McPike Zima Charitable Foundation.
Abstract (Originalsprache)
FTIR spectral identification is today’s gold standard analytical procedure for plastic pollution material characterization. High-throughput FTIR techniques have been advanced for small microplastics (10–500 µm) but less so for large microplastics (500–5 mm) and macroplastics (> 5 mm). These larger plastics are typically analyzed using ATR, which is highly manual and can sometimes destroy particles of interest. Furthermore, spectral libraries are often inadequate due to the limited variety of reference materials and spectral collection modes, resulting from expensive spectral data collection. We advance a new high-throughput technique to remedy these problems using FTIR microplate readers for measuring large particles (> 500 µm). We created a new reference database of over 6000 spectra for transmission, ATR, and reflection spectral collection modes with over 600 plastic, organic, and mineral reference materials relevant to plastic pollution research. We also streamline future analysis in microplate readers by creating a new particle holder for transmission measurements using off-the-shelf parts and fabricating a nonplastic 96-well microplate for storing particles. We determined that particles should be presented to microplate readers as thin as possible due to thick particles causing poor-quality spectra and identifications. We validated the new database using Open Specy and demonstrated that additional transmission and reflection spectra reference data were needed in spectral libraries. Graphical abstract
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Moore Institute for Plastic Pollution Research, Long Beach, CA, USA. wincowger@gmail.com.
- Alfred Wegener Institute Helmholtz Centre for Polar and Marine Research, Helgoland, Germany. wincowger@gmail.com.
- University of California, Riverside, CA, USA. wincowger@gmail.com.
- Alfred Wegener Institute Helmholtz Centre for Polar and Marine Research, Helgoland, Germany.
- National Renewable Energy Laboratory, Golden, CO, USA.
- Alfred Wegener Institute Helmholtz Centre for Polar and Marine Research, Helgoland, Germany. sebastian.primpke@awi.de.
Förderung
- National Renewable Energy Laboratory
- Possibility Lab
- McPike Zima Charitable Foundation
- Helmholtz Data Science Academy
Zitieren
APA
Cowger, W., Roscher, L., Jebens, H., Chamas, A., Maurer, B. D., Gehrke, L., Gerdts, G., & Primpke, S. (2024). Generation of macro- and microplastic databases by high-throughput FTIR analysis with microplate readers. Analytical and Bioanalytical Chemistry, 416(6), 1311-1320. https://doi.org/10.1007/s00216-024-05127-w
Vancouver
Cowger W, Roscher L, Jebens H, Chamas A, Maurer BD, Gehrke L, et al. Generation of macro- and microplastic databases by high-throughput FTIR analysis with microplate readers. Analytical and Bioanalytical Chemistry. 2024;416(6):1311-1320. doi:10.1007/s00216-024-05127-w
BibTeX
@article{Cowger2024,
author = {Cowger, Win and Roscher, Lisa and Jebens, Hannah and Chamas, Ali and Maurer, Benjamin D and Gehrke, Lukas and Gerdts, Gunnar and Primpke, Sebastian},
title = {Generation of macro- and microplastic databases by high-throughput FTIR analysis with microplate readers},
journal = {Analytical and Bioanalytical Chemistry},
year = {2024},
volume = {416},
number = {6},
pages = {1311--1320},
doi = {10.1007/s00216-024-05127-w}
}
EUVIMED