EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

In-house validation of an LC–MS method for the multiplexed quantitative determination of total allergenic food in chocolate

Rosa Pilolli, Antonella Lamonaca, Chiara Nitride, Elisabetta De Angelis, Christof van Poucke, Nathalie Gillard, Anne-Catherine Huet, Marc De Loose, Jean Henrottin, E C N Mills, Linda Monaci

Analytical and Bioanalytical Chemistry · 2024-01 · 416 (3) · 809-825

DOI: 10.1007/s00216-023-04894-2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, online erschienen am 24.08.2023. Verfasst von Rosa Pilolli und 10 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Sciences of Food Production, National Research Council of Italy (ISPA-CNR), Via Giovanni Amendola 122/O, 70126, Bari, Italy. rosa.piloll…. Hauptthemen laut MEDLINE: Chocolate, Food Hypersensitivity, Cacao. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Food Safety Authority.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Mass spectrometry has been widely accepted as a confirmatory tool for the sensitive detection of undeclared presence of allergenic ingredients. Multiple methods have been developed so far, achieving different levels of sensitivity and robustness, still lacking harmonization of the analytical validation and impairing comparability of results. In this investigation, a quantitative method has been validated in-house for the determination of six allergenic ingredients (cow’s milk, hen’s egg, peanut, soybean, hazelnut, and almond) in a chocolate-based matrix. The latter has been produced in a food pilot plant to provide a real and well-characterized matrix for proper assessment of method performance characteristics according to official guidelines. In particular, recent considerations issued by the European Committee for Standardization have been followed to guide a rigorous single-laboratory validation and to feature the main method performance, such as selectivity, linearity, and sensitivity. Synthetic surrogates of the peptide markers have been used both in native and labelled forms in matrix-matched calibration curves as external calibrants and internal standards, respectively. A two-order of magnitude range was investigated, focusing on the low concentration range for proper assessment of the detection and quantification limits (LOD and LOQ) by rigorous calibration approach. Conversion factors for all six allergenic ingredients have been determined for the first time to report the final quantitative information as fraction of total allergenic food protein (TAFP) per mass of food (µg TAFP /g food ), since such a reporting unit is exploitable in allergenic risk assessment plans. The method achieved good sensitivity with LOD values ranging between 0.08 and 0.2 µg TAFP /g food , for all ingredients besides egg and soybean, whose quantitative markers reported a slightly higher limit (1.1 and 1.2 µg TAFP /g food , respectively). Different samples of chocolate bar incurred at four defined concentration levels close to the currently available threshold doses have been analyzed to test the quantitative performance of the analytical method, with a proper estimate of the measurement uncertainty from different sources of variability. The sensitivity achieved resulted in compliance with the various threshold doses issued or recommended worldwide.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ChocolateFood HypersensitivityCacaoCattleAnimalsFemaleLiquid Chromatography-Mass SpectrometryChromatography, LiquidChickensTandem Mass SpectrometryEggsAllergensFood Analysis

Stichwörter der Autor:innen

Conversion factorsFood allergenIn-house validationMass spectrometryQuantitative methodUncertainty

Substanzen

Allergens

Autor:innen und Institutionen

  • Institute of Sciences of Food Production, National Research Council of Italy (ISPA-CNR), Via Giovanni Amendola 122/O, 70126, Bari, Italy. rosa.pilolli@ispa.cnr.it.
  • Institute of Sciences of Food Production, National Research Council of Italy (ISPA-CNR), Via Giovanni Amendola 122/O, 70126, Bari, Italy.
  • University of Bari Department of Soil Plant and Food Science, Via Giovanni Amendola 165/A, 70126, Bari, Italy.
  • Department of Agricultural Sciences, University of Naples Federico II, Via Università 100, 80055, Portici, Italy.
  • School of Biological Sciences, Division of Infection, Immunity and Respiratory Medicine, Manchester Academic Health Science Centre, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK.
  • Flanders Research Institute for Agriculture, Fisheries and Food, Brusselsesteenweg 370, 9090, Melle, Belgium.

Förderung

  • European Food Safety Authority

Zitieren

APA

Pilolli, R., Lamonaca, A., Nitride, C., De Angelis, E., van Poucke, C., Gillard, N., Huet, A. C., De Loose, M., Henrottin, J., Mills, E. C. N., & Monaci, L. (2024). In-house validation of an LC–MS method for the multiplexed quantitative determination of total allergenic food in chocolate. Analytical and Bioanalytical Chemistry, 416(3), 809-825. https://doi.org/10.1007/s00216-023-04894-2

Vancouver

Pilolli R, Lamonaca A, Nitride C, De Angelis E, van Poucke C, Gillard N, et al. In-house validation of an LC–MS method for the multiplexed quantitative determination of total allergenic food in chocolate. Analytical and Bioanalytical Chemistry. 2024;416(3):809-825. doi:10.1007/s00216-023-04894-2

BibTeX
@article{Pilolli2024,
  author = {Pilolli, Rosa and Lamonaca, Antonella and Nitride, Chiara and De Angelis, Elisabetta and van Poucke, Christof and Gillard, Nathalie and Huet, Anne-Catherine and De Loose, Marc and Henrottin, Jean and Mills, E C N and Monaci, Linda},
  title = {In-house validation of an LC–MS method for the multiplexed quantitative determination of total allergenic food in chocolate},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2024},
  volume = {416},
  number = {3},
  pages = {809--825},
  doi = {10.1007/s00216-023-04894-2}
}
Kostenlos starten →