EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Point-of-care diagnostics for rapid determination of prostate cancer biomarker sarcosine: application of disposable potentiometric sensor based on oxide-conductive polymer nanocomposite

Hend Z Yamani, Nardine Safwat, Amr M Mahmoud, Miriam F Ayad, Maha F Abdel-Ghany, Mohammed M Gomaa

Analytical and Bioanalytical Chemistry · 2023

DOI: 10.1007/s00216-023-04818-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2023. Verfasst von Hend Z Yamani und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt. Hauptthemen laut MEDLINE: Prostatic Neoplasms, Nanocomposites. Die Arbeit wurde bisher 28-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Academy of Scientific Research and Technology, Ain Shams University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

One of the most important reasons for an increased mortality rate of cancer is late diagnosis. Point-of-care (POC) diagnostic sensors can provide rapid and cost-effective diagnosis and monitoring of cancer biomarkers. Portable, disposable, and sensitive sarcosine solid-contact ion-selective potentiometric sensors (SC-ISEs) were fabricated as POC analyzers for the rapid determination of the prostate cancer biomarker sarcosine. Tungsten trioxide nanoparticles (WO 3 NPs), polyaniline nanoparticles (PANI NPs), and PANI-WO 3 nanocomposite were used as ion-to-electron transducers on screen-printed sensors. WO 3 NPs and PANI-WO 3 nanocomposite have not been investigated before as ion-to-electron transducer layers in potentiometric SC sensors. The designated sensors were characterized using SEM, XRD, FTIR, UV-VIS spectroscopy, and EIS. The inclusion of WO 3 and PANI in SC sensors enhanced the transduction at the interface between the screen-printed SC and the ion-selective membrane, offering lower potential drift, a longer lifetime, shorter response time, and better sensitivity. The proposed sarcosine sensors exhibited Nernstian slopes over linear response ranges 10 −3 –10 −7 M, 10 −3 –10 −8 M, 10 −5 –10 −9 M, and 10 −7 –10 −12 M for control, WO 3 NPs, PANI NPs, and PANI-WO 3 nanocomposite-based sensors, respectively. From a comparative point of view between the four sensors, PANI-WO 3 nanocomposite inclusion offered the lowest potential drift (0.5 mV h −1 ), the longest lifetime (4 months), and the best LOD (9.95 × 10 −13 M). The proposed sensors were successfully applied to determine sarcosine as a potential prostate cancer biomarker in urine without prior sample treatment steps. The WHO ASSURED criteria for point-of-care diagnostics are met by the proposed sensors. Graphical abstract

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prostatic NeoplasmsNanocompositesMaleHumansBiomarkers, TumorSarcosineProstatePolymersOxidesPoint-of-Care Testing

Stichwörter der Autor:innen

Ion-to-electron transducersPoint-of-care diagnosticsPolyaniline-tungsten trioxide nanocompositeSarcosine ion-selective electrodeSolid contact sensorsTungsten trioxide nanoparticles

Substanzen

Biomarkers, TumorSarcosinePolymersOxides

Autor:innen und Institutionen

  • Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt.
  • Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, Cairo, 11566, Egypt. nardine.safwat2@pharma.asu.edu.eg.
  • Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Cairo University, Cairo, 11562, Egypt. amr.bekhet@pharma.cu.edu.eg.
  • Solid State Physics Department, National Research Centre, Giza, 12622, Egypt.

Förderung

  • Academy of Scientific Research and Technology
  • Ain Shams University

Zitieren

APA

Yamani, H. Z., Safwat, N., Mahmoud, A. M., Ayad, M. F., Abdel-Ghany, M. F., & Gomaa, M. M. (2023). Point-of-care diagnostics for rapid determination of prostate cancer biomarker sarcosine: application of disposable potentiometric sensor based on oxide-conductive polymer nanocomposite. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-023-04818-0

Vancouver

Yamani HZ, Safwat N, Mahmoud AM, Ayad MF, Abdel-Ghany MF, Gomaa MM. Point-of-care diagnostics for rapid determination of prostate cancer biomarker sarcosine: application of disposable potentiometric sensor based on oxide-conductive polymer nanocomposite. Analytical and Bioanalytical Chemistry. 2023. doi:10.1007/s00216-023-04818-0

BibTeX
@article{Yamani2023,
  author = {Yamani, Hend Z and Safwat, Nardine and Mahmoud, Amr M and Ayad, Miriam F and Abdel-Ghany, Maha F and Gomaa, Mohammed M},
  title = {Point-of-care diagnostics for rapid determination of prostate cancer biomarker sarcosine: application of disposable potentiometric sensor based on oxide-conductive polymer nanocomposite},
  journal = {Analytical and Bioanalytical Chemistry},
  year = {2023},
  doi = {10.1007/s00216-023-04818-0}
}
Kostenlos starten →