Comparison of gas chromatographic techniques for the analysis of iodinated derivatives of aromatic amines
Analytical and Bioanalytical Chemistry · 2023
DOI: 10.1007/s00216-023-04713-8 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2023. Verfasst von Nerea Lorenzo-Parodi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Amines. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Evonik Industries, Universität Duisburg-Essen.
Abstract (Originalsprache)
Some aromatic amines (AA) have been classified as carcinogens to humans. After entering the body, mainly through tobacco smoke, they can be detected in urine. Thus, their trace analysis as biomarkers in biofluids is of high relevance and can be achieved with gas chromatography (GC–MS), usually after derivatization. This study compares three gas chromatographic methods for the analysis of ten iodinated derivatives of AA: GC–MS in single-ion monitoring (SIM) mode with (1) electron ionization (GC-EI-MS) and (2) negative chemical ionization (GC-NCI-MS), and (3) GC-EI-MS/MS in multiple reaction monitoring (MRM) mode using electron ionization. All methods and most analytes showed good coefficients of determination ( R 2 > 0.99) for broad linear ranges covering three to five orders of magnitude in the picogram-per-liter to nanogram-per-liter range, with one and two exceptions for (1) and (2) respectively. Excellent limits of detection (LODs) of 9–50, 3.0–7.3, and 0.9–3.9 pg/L were observed for (1), (2), and (3) respectively, and good precision was achieved (intra-day repeatability < 15% and inter-day repeatability < 20% for most techniques and concentration levels). On average, recoveries between 80 and 104% were observed for all techniques. Urine samples of smokers and non-smokers were successfully analyzed, and p-toluidine and 2-chloroaniline could be found at significantly ( α = 0.05) higher concentrations among smokers. Graphical Abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany.
- Institute of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9/II 8010, Graz, Austria.
- Instrumental Analytical Chemistry, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. torsten.schmidt@uni-due.de.
- Centre for Water and Environmental Research, University of Duisburg-Essen, Universitätsstrasse 5, 45141, Essen, Germany. torsten.schmidt@uni-due.de.
- IWW Water Centre, Moritzstrasse 26, 45476, Mülheim an Der Ruhr, Germany. torsten.schmidt@uni-due.de.
Förderung
- Evonik Industries
- Universität Duisburg-Essen
Zitieren
APA
Lorenzo-Parodi, N., Leitner, E., & Schmidt, T. C. (2023). Comparison of gas chromatographic techniques for the analysis of iodinated derivatives of aromatic amines. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-023-04713-8
Vancouver
Lorenzo-Parodi N, Leitner E, Schmidt TC. Comparison of gas chromatographic techniques for the analysis of iodinated derivatives of aromatic amines. Analytical and Bioanalytical Chemistry. 2023. doi:10.1007/s00216-023-04713-8
BibTeX
@article{LorenzoParodi2023,
author = {Lorenzo-Parodi, Nerea and Leitner, Erich and Schmidt, Torsten C},
title = {Comparison of gas chromatographic techniques for the analysis of iodinated derivatives of aromatic amines},
journal = {Analytical and Bioanalytical Chemistry},
year = {2023},
doi = {10.1007/s00216-023-04713-8}
}
EUVIMED