EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimal design and performance analysis of coastal microgrid using different optimization algorithms

Abualkasim Bakeer, Mahmoud F. Elmorshedy, Hossam S. Salama, Mohamed R. Elkadeem, Dhafer J. Almakhles, Kotb M. Kotb

Electrical Engineering · 2023-12 · 105 (6) · 4499-4523

DOI: 10.1007/s00202-023-01954-9 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Electrical Engineering, online erschienen am 28.08.2023. Verfasst von Abualkasim Bakeer und 5 weiteren Autor:innen. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 74 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Tanta University.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Owing to the stochastic behavior of renewable energy activity and the multiple design considerations, the advancement of hybrid renewable energy-based microgrid (HREMG) systems has become a complex task. This study proposes a design optimization algorithm for the long-term operation of an autonomous HREMG along with the optimal system capacities. The investigated energy system comprises photovoltaic panels, wind turbines, diesel generators, and batteries. It aims to energize a remote coastal community with a daily load demand of 400 kWh in Marsa Matruh, Egypt. Since most studies utilize commercial tools in the design optimization procedure, the African vultures optimization approach (AVOA) is developed to find the optimal energy alternative and determine the optimal component’s capacity considering achieving the minimum energy cost and loss of power supply probability. Moreover, an adequate energy management strategy is suggested to coordinate the power flow within the energy system in which renewable energy sources are fully penetrated. To check the AVOA robustness and efficacy, its performance is compared with the HOMER Pro most popular commercial tool as well as with new metaheuristic algorithms, namely the grasshopper optimization algorithm (GOA) and Giza pyramid construction (GPC) under the same operating environment. The results revealed that the proposed AVOA achieved superior economic results toward the least net present cost ($346,614) and energy price (0.0947 $/kWh). Moreover, over 20 independent runs, the AVOA showed a better performance in terms of convergence and execution time compared to other tools/algorithms. The obtained findings could be a useful benchmark for researchers in the sizing problem of hybrid energy systems.

Förderung

  • Tanta University

Zitieren

APA

Bakeer, A., Elmorshedy, M. F., Salama, H. S., Elkadeem, M. R., Almakhles, D. J., & Kotb, K. M. (2023). Optimal design and performance analysis of coastal microgrid using different optimization algorithms. Electrical Engineering, 105(6), 4499-4523. https://doi.org/10.1007/s00202-023-01954-9

Vancouver

Bakeer A, Elmorshedy MF, Salama HS, Elkadeem MR, Almakhles DJ, Kotb KM. Optimal design and performance analysis of coastal microgrid using different optimization algorithms. Electrical Engineering. 2023;105(6):4499-4523. doi:10.1007/s00202-023-01954-9

BibTeX
@article{Bakeer2023,
  author = {Bakeer, Abualkasim and Elmorshedy, Mahmoud F. and Salama, Hossam S. and Elkadeem, Mohamed R. and Almakhles, Dhafer J. and Kotb, Kotb M.},
  title = {Optimal design and performance analysis of coastal microgrid using different optimization algorithms},
  journal = {Electrical Engineering},
  year = {2023},
  volume = {105},
  number = {6},
  pages = {4499--4523},
  doi = {10.1007/s00202-023-01954-9}
}