Patients’ Perspectives and Challenges with Sacral Neuromodulation Implantable Pulse Generator

Mazen Mansour, Alexander Fahmy, Maria D'Amico, Mohammad El Hussein, Tyler Trump, Mahmoud Abou Zeinab, Ahmad Albakr, Howard B Goldman

International Urogynecology Journal · 2026-10 · 37 (10) · 3445-3449

DOI: 10.1007/s00192-026-06756-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Urogynecology Journal, online erschienen am 09.06.2026. Verfasst von Mazen Mansour und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cleveland Clinic Foundation Glickman Urologic and Kidney Institute, Cleveland, OH, USA. mansoum6@ccf.org. Hauptthemen laut MEDLINE: Urinary Bladder, Overactive, Electric Stimulation Therapy, Patient Satisfaction, Fecal Incontinence. Die Arbeit nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Sacral neuromodulation (SNM) is an established therapy for refractory bowel and lower urinary tract dysfunction. While its efficacy and patient satisfaction are well documented, little is known about the physical burden of the implant itself. This study aimed to evaluate patient perspectives on the implantable pulse generator (IPG) placed in the gluteal region.

Methods

We reviewed 100 consecutive patients who underwent SNM within the past 2 years at a tertiary care center. Data were collected during follow-up visits or phone interviews using a five-question survey based on common patient concerns. Responses were analyzed descriptively, with statistical testing performed using SPSS version 29.

Results

Eighty-two patients received SNM for overactive bladder, 16 for urinary retention, and two for fecal incontinence. Sixty-two percent reported awareness of the IPG, 18% reported sleep or movement limitations, and 36% reported activity-related discomfort. Eleven percent turned off the device for non-MRI reasons. Overweight or obese patients (BMI >25) were less likely to report disturbances compared with normal-weight patients. Male patients were more likely than female patients to deactivate their device ( P = 0.014), while older patients were less likely to turn it off.

Discussion

Most patients tolerated SNM well, though lower BMI was associated with greater discomfort, consistent with prior reports of higher revision rates in leaner individuals. Sex- and age-related differences suggest variations in device use behaviors, possibly due to lifestyle, activity level, or technological engagement.

Conclusion

SNM is generally well tolerated, but leaner, younger, and male patients may experience greater device-related burden, highlighting the need for tailored counseling and device optimization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Urinary Bladder, OveractiveElectric Stimulation TherapyPatient SatisfactionFecal IncontinenceUrinary RetentionImplantable NeurostimulatorsHumansFemaleMaleMiddle AgedAgedAdultLumbosacral PlexusSacrumAged, 80 and overElectrodes, ImplantedRetrospective Studies

Stichwörter der Autor:innen

Body mass indexDevice tolerabilityImplantable pulse generatorOveractive bladderPatient-reported outcomesSacral neuromodulationUrinary incontinence

Autor:innen und Institutionen

  • Cleveland Clinic Foundation Glickman Urologic and Kidney Institute, Cleveland, OH, USA. mansoum6@ccf.org.
  • Drexel University College of Medicine, Philadelphia, PA, USA.
  • Cleveland Clinic Foundation Glickman Urologic and Kidney Institute, Cleveland, OH, USA.

Zitieren

APA

Mansour, M., Fahmy, A., D'Amico, M., Hussein, M. E., Trump, T., Zeinab, M. A., Albakr, A., & Goldman, H. B. (2026). Patients’ Perspectives and Challenges with Sacral Neuromodulation Implantable Pulse Generator. International Urogynecology Journal, 37(10), 3445-3449. https://doi.org/10.1007/s00192-026-06756-8

Vancouver

Mansour M, Fahmy A, D'Amico M, Hussein ME, Trump T, Zeinab MA, et al. Patients’ Perspectives and Challenges with Sacral Neuromodulation Implantable Pulse Generator. International Urogynecology Journal. 2026;37(10):3445-3449. doi:10.1007/s00192-026-06756-8

BibTeX
@article{Mansour2026,
  author = {Mansour, Mazen and Fahmy, Alexander and D'Amico, Maria and Hussein, Mohammad El and Trump, Tyler and Zeinab, Mahmoud Abou and Albakr, Ahmad and Goldman, Howard B},
  title = {Patients’ Perspectives and Challenges with Sacral Neuromodulation Implantable Pulse Generator},
  journal = {International Urogynecology Journal},
  year = {2026},
  volume = {37},
  number = {10},
  pages = {3445--3449},
  doi = {10.1007/s00192-026-06756-8}
}
Kostenlos starten →