EUVIMEDEUVIMED entdecken
Vergleichsstudie

High degree of alignment precision associated with total knee arthroplasty performed using a surgical robot or handheld navigation

Tony S Shen, Tyler J Uppstrom, Paul J Walker, Jonathan S Yu, Ryan Cheng, David J Mayman, Seth A Jerabek, Michael P Ast

Knee Surgery, Sports Traumatology, Arthroscopy · 2023-11 · 31 (11) · 4735-4740

DOI: 10.1007/s00167-023-07495-9 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, online erschienen am 29.06.2023. Verfasst von Tony S Shen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA. shent@hss.edu. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee, Robotic Surgical Procedures, Surgery, Computer-Assisted, Surgical Navigation Systems. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 27 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to compare the precision of bony resections during total knee arthroplasty (TKA) performed using different computer‐assisted technologies.

Methods

Patients who underwent a primary TKA using an imageless accelerometer‐based handheld navigation system (KneeAlign2®, OrthAlign Inc.) or computed tomography‐based large‐console surgical robot (Mako®, Stryker Corp.) from 2017 to 2020 were retrospectively reviewed. Templated alignment targets and demographic data were collected. Coronal plane alignment of the femoral and tibial components and tibial slope were measured on postoperative radiographs. Patients with excessive flexion or rotation preventing accurate measurement were excluded.

Results

A total of 240 patients who underwent TKA using either a handheld ( n = 120) or robotic ( n = 120) system were included. There were no statistically significant differences in age, sex, and BMI between groups. A small but statistically significant difference in the precision of the distal femoral resection was observed between the handheld and robotic cohorts (1.5° vs. 1.1° difference between templated and measured alignments, p = 0.024), though this is likely clinically insignificant. There were no significant differences in the precision of the tibial resection between the handheld and robotic groups (coronal plane 0.9° vs. 1.0°, n.s.; sagittal plane 1.2° vs. 1.1°, n.s.). There were no significant differences in the rate of overall precision between cohorts (n.s.).

Conclusions

A high degree of component alignment precision was observed for both imageless handheld navigation and CT‐based robotic cohorts. Surgeons considering options for computer‐assisted TKA should take other important factors, including surgical principles, templating software, ligament balancing, intraoperative adjustability, equipment logistics, and cost, into account. Level of evidence III.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, KneeRobotic Surgical ProceduresSurgery, Computer-AssistedSurgical Navigation SystemsHumansMaleFemaleRetrospective StudiesAgedMiddle AgedTibiaFemurAged, 80 and overKnee Joint

Stichwörter der Autor:innen

Coronal alignmentEnabling technologyImageless navigationRoboticsTotal knee arthroplasty

Autor:innen und Institutionen

  • Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA. shent@hss.edu.
  • Adult Reconstruction and Joint Replacement Service, Hospital for Special Surgery, 535 East 70th Street, New York, NY, 10021, USA.
  • Department of Orthopaedic Surgery, UCLA, Los Angeles, CA, USA.

Zitieren

APA

Shen, T. S., Uppstrom, T. J., Walker, P. J., Yu, J. S., Cheng, R., Mayman, D. J., Jerabek, S. A., & Ast, M. P. (2023). High degree of alignment precision associated with total knee arthroplasty performed using a surgical robot or handheld navigation. Knee Surgery, Sports Traumatology, Arthroscopy, 31(11), 4735-4740. https://doi.org/10.1007/s00167-023-07495-9

Vancouver

Shen TS, Uppstrom TJ, Walker PJ, Yu JS, Cheng R, Mayman DJ, et al. High degree of alignment precision associated with total knee arthroplasty performed using a surgical robot or handheld navigation. Knee Surgery, Sports Traumatology, Arthroscopy. 2023;31(11):4735-4740. doi:10.1007/s00167-023-07495-9

BibTeX
@article{Shen2023,
  author = {Shen, Tony S and Uppstrom, Tyler J and Walker, Paul J and Yu, Jonathan S and Cheng, Ryan and Mayman, David J and Jerabek, Seth A and Ast, Michael P},
  title = {High degree of alignment precision associated with total knee arthroplasty performed using a surgical robot or handheld navigation},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2023},
  volume = {31},
  number = {11},
  pages = {4735--4740},
  doi = {10.1007/s00167-023-07495-9}
}
Kostenlos starten →