MCL internal brace does not fully recapitulate normal MCL function in valgus stress
Knee Surgery, Sports Traumatology, Arthroscopy · 2023
DOI: 10.1007/s00167-023-07438-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2023. Verfasst von Marc A Tompkins und 3 weiteren Autor:innen. Beteiligte Einrichtung: TRIA Orthopaedic Center, 8100 Northland Drive, Bloomington, MN, 55431, USA. marc.tompkins@tria.com. Hauptthemen laut MEDLINE: Medial Collateral Ligament, Knee, Joint Instability. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 34 Literaturangaben.
Abstract (Originalsprache)
Purpose
The null hypothesis is that there would be no difference in medial gapping under valgus load between the intact MCL and the ruptured MCL with an internal brace in place.
Methods
Eight pairs of cadaver knees were used (16 knees). Alternating sides, one knee from each pair was used for one of two “internal brace” constructs. The constructs involved different methods of fixation for securing FiberTape (Arthrex, Naples, FL) to both the femur and tibia in an effort to brace the MCL. The knees were then subjected to valgus stress by applying 10 N m of torque with the knee at 20 degrees of flexion. The amount of medial joint space opening was measured on radiographs. The stress testing was conducted with three MCL states: intact, grade 2 tear, and grade 3 tear.
Results
In the Construct I specimens, gapping increased from 0.7 mm with the MCL intact to 1.1 mm with grade 2 tearing ( p < 0.01), and to 1.3 mm with grade 3 tearing ( p < 0.01). In the Construct II specimens, gapping increased from 0.7 mm with the MCL intact to 1.0 mm with grade 2 tearing ( p < 0.01), and to 1.1 mm with grade 3 tearing (n.s.). Construct I specimens failed primarily at the femoral attachment. All Construct II specimens survived the valgus stress testing.
Conclusion
Construct I did not maintain tension. Construct II did maintain tension during application of valgus load, but did not restore valgus opening to the intact state. It is important for clinicians who are considering using this commercially available technique to be aware of how the construct performs under valgus stress testing compared to the intact MCL.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- TRIA Orthopaedic Center, 8100 Northland Drive, Bloomington, MN, 55431, USA. marc.tompkins@tria.com.
- Department of Orthopaedic Surgery, University of Minnesota, 2450 Riverside Avenue South, Suite R200, Minneapolis, MN, 55454, USA. marc.tompkins@tria.com.
- College of Science and Engineering, University of Minnesota, 117 Pleasant Street SE, Minneapolis, MN, 55455, USA.
- Excelen Center for Bone and Joint Research and Education, 700 10th Avenue South, Minneapolis, MN, 55415, USA.
- Department of Orthopaedic Surgery, University of Minnesota, 2450 Riverside Avenue South, Suite R200, Minneapolis, MN, 55454, USA.
Zitieren
APA
Tompkins, M. A., Freeman, A. L., Hursh, E., & Bechtold, J. E. (2023). MCL internal brace does not fully recapitulate normal MCL function in valgus stress. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-023-07438-4
Vancouver
Tompkins MA, Freeman AL, Hursh E, Bechtold JE. MCL internal brace does not fully recapitulate normal MCL function in valgus stress. Knee Surgery, Sports Traumatology, Arthroscopy. 2023. doi:10.1007/s00167-023-07438-4
BibTeX
@article{Tompkins2023,
author = {Tompkins, Marc A and Freeman, Andrew L and Hursh, Elliot and Bechtold, Joan E},
title = {MCL internal brace does not fully recapitulate normal MCL function in valgus stress},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2023},
doi = {10.1007/s00167-023-07438-4}
}
EUVIMED