EUVIMEDEUVIMED entdecken
Crossref

The tibial tunnel drilling angles of 60° provided a lower ultimate load to failure on a single bundle posterior cruciate ligament graft using interference screw fixation compared to 30°/45°

Xiaohui Zhang, Fei Teng, Bin Geng, Fan Lu, Zhongcheng Liu, Laiwei Guo, Hua Han, Meng Wu, Yayi Xia, Yuanjun Teng

Knee Surgery, Sports Traumatology, Arthroscopy · 2023

DOI: 10.1007/s00167-023-07428-6 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2023. Verfasst von Xiaohui Zhang und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Orthopaedics Clinical Medical Research Center of Gansu Province, Lanzhou University Second Hospital, Lanzhou University, …. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament Reconstruction, Posterior Cruciate Ligament. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Natural Science Foundation of China, Cuiying Scientific and technological innovation program of Lanzhou University Second Hospital, Medical Innovation and Development Project of Lanzhou University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To biomechanically compare the initial fixation strength of grafts among three tibial tunnel angles (30°/45°/60°) in transtibial posterior cruciate ligament (PCL) reconstruction.

Methods

A series of transtibial PCL reconstruction models were established with porcine tibias and bovine tendons. Specimens were randomly assigned to three groups according to the angles between the tibial tunnel and the perpendicular line of the tibial shaft: Group A (30°, n = 12), Group B (45°, n = 12), and Group C (60°, n = 12). The area of the tunnel entrance, the segmental bone mineral density (sBMD) of the graft fixation site of the tibia and the maximum insertion torque of the interference screw were measured. Finally, load to failure tests were carried out on the graft‐screw‐tibia constructs at the same rate.

Results

Ultimate load to failure in Group C (335.2 ± 107.5 N) was significantly lower than that in Group A (584.1 ± 127.9 N, P < 0.01) and Group B (521.9 ± 95.9 N, P < 0.01). There were no significant differences between biomechanical properties of Groups A and B (n.s.). The posterior part fractures of the tibial tunnel exit occurred in eight specimens of Group C. In addition, the ultimate load was proven to be related to insertion torque (rho = 0.7, P < 0.01), sBMD (rho = 0.7, P < 0.01), and the area of the tunnel entrance (rho =− 0.4, P = 0.01).

Conclusion

The ultimate load to failure was significantly lower in tibial PCL interference screw fixation for tunnels drilled at 60° compared to 30°/45°. In addition, the ultimate load was significantly correlated with insertion torque, sBMD and the area of the tunnel entrance. Given that the load to failure of distal fixation may not be sufficient for early postoperative rehabilitation, a 60° tunnel should not be recommended to drill in tibia during PCL reconstruction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anterior Cruciate Ligament ReconstructionPosterior Cruciate LigamentAnimalsCattleBiomechanical PhenomenaBone ScrewsSwineTibia

Stichwörter der Autor:innen

BiomechanicsPosterior cruciate ligament (PCL) reconstructionTibial tunnel angle

Autor:innen und Institutionen

  • Department of Orthopaedics, Orthopaedics Clinical Medical Research Center of Gansu Province, Lanzhou University Second Hospital, Lanzhou University, No. 82 Cuiyingmen, Chengguan District, Lanzhou, 730030, Gansu, People'…

Förderung

  • Natural Science Foundation of China
  • Cuiying Scientific and technological innovation program of Lanzhou University Second Hospital
  • Medical Innovation and Development Project of Lanzhou University
  • Gansu Natural Science Foundation Youth Project
  • National Natural Science Foundation of China

Zitieren

APA

Zhang, X., Teng, F., Geng, B., Lu, F., Liu, Z., Guo, L., Han, H., Wu, M., Xia, Y., & Teng, Y. (2023). The tibial tunnel drilling angles of 60° provided a lower ultimate load to failure on a single bundle posterior cruciate ligament graft using interference screw fixation compared to 30°/45°. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-023-07428-6

Vancouver

Zhang X, Teng F, Geng B, Lu F, Liu Z, Guo L, et al. The tibial tunnel drilling angles of 60° provided a lower ultimate load to failure on a single bundle posterior cruciate ligament graft using interference screw fixation compared to 30°/45°. Knee Surgery, Sports Traumatology, Arthroscopy. 2023. doi:10.1007/s00167-023-07428-6

BibTeX
@article{Zhang2023,
  author = {Zhang, Xiaohui and Teng, Fei and Geng, Bin and Lu, Fan and Liu, Zhongcheng and Guo, Laiwei and Han, Hua and Wu, Meng and Xia, Yayi and Teng, Yuanjun},
  title = {The tibial tunnel drilling angles of 60° provided a lower ultimate load to failure on a single bundle posterior cruciate ligament graft using interference screw fixation compared to 30°/45°},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2023},
  doi = {10.1007/s00167-023-07428-6}
}
Kostenlos starten →