Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts
Knee Surgery, Sports Traumatology, Arthroscopy · 2023
DOI: 10.1007/s00167-023-07406-y ↗Kurz gefasst
Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2023. Verfasst von Jiewen Luo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament Reconstruction, Patellar Ligament, Anterior Cruciate Ligament Injuries. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: The Wisdom Accumulation and Talent Cultivation Project of the Third Xiangya Hospital of Central South University.
Abstract (Originalsprache)
Purpose
This study aimed to determine the correlation between the intraoperative diameter of double‐stranded peroneus longus tendon (2PLT) and length of the PLT autograft and preoperative ultrasound (US) measurements, as well as radiographic and anthropometric measurements. The hypothesis was that US can accurately predict the diameter of 2PLT autografts during operation.
Methods
Twenty‐six patients underwent ligament reconstruction with 2PLT autografts were included. Preoperative US was used to calculate the in situ PLT cross‐sectional area (CSA) at seven levels (0, 1, 2, 3, 4, 5, 10 cm proximal to the harvest start point). Femoral width, notch width, notch height, maximum patellar length, and patellar tendon length were determined on preoperative radiographs. Intraoperative measurements of PLT were made, including all fiber lengths of PLT and diameters of 2PLT using sizing tubes calibrated to 0.5 mm.
Results
CSA at 1 cm proximal to the harvest site had the highest correlation with the diameter of 2PLT ( r = 0.84, P < 0.001). Calf length had the highest correlation with PLT length ( r = 0.65, P < 0.001). The diameter of the 2PLT autografts could be predicted by the following formula: 4.6 + 0.2 × [sonographic CSA of PLT at 1 cm level]; the length of PLT could be predicted by the following formula: 5.6 + 0.5 × Calf length.
Conclusion
The diameter of 2PLT and length of PLT autografts can be accurately predicted by preoperative US and calf length measurements, respectively. Accurate preoperative prediction of the diameter and length of autologous grafts can provide the most suitable and individualized graft for patients. Level of evidence IV.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China.
- Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, 15213, USA.
- Department of Anesthesiology, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China.
- School of Mathematics and Statistics, Central South University, Changsha, 410083, Hunan, China.
- Department of Orthopaedic Surgery, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China. jinshen.he@hotmail.com.
Förderung
- The Wisdom Accumulation and Talent Cultivation Project of the Third Xiangya Hospital of Central South University
Zitieren
APA
Luo, J., Wu, S., Rothrauff, B., Liao, Q., Feng, J., Tan, L., Cao, Y., Liang, J., Wang, J., & He, J. (2023). Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-023-07406-y
Vancouver
Luo J, Wu S, Rothrauff B, Liao Q, Feng J, Tan L, et al. Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts. Knee Surgery, Sports Traumatology, Arthroscopy. 2023. doi:10.1007/s00167-023-07406-y
BibTeX
@article{Luo2023,
author = {Luo, Jiewen and Wu, Song and Rothrauff, Benjamin and Liao, Qin and Feng, Jing and Tan, Lingjie and Cao, Yangbo and Liang, Jiehui and Wang, Jiaoju and He, Jinshen},
title = {Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2023},
doi = {10.1007/s00167-023-07406-y}
}
EUVIMED