EUVIMEDEUVIMED entdecken
Crossref

Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts

Jiewen Luo, Song Wu, Benjamin Rothrauff, Qin Liao, Jing Feng, Lingjie Tan, Yangbo Cao, Jiehui Liang, Jiaoju Wang, Jinshen He

Knee Surgery, Sports Traumatology, Arthroscopy · 2023

DOI: 10.1007/s00167-023-07406-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2023. Verfasst von Jiewen Luo und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China. Hauptthemen laut MEDLINE: Anterior Cruciate Ligament Reconstruction, Patellar Ligament, Anterior Cruciate Ligament Injuries. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: The Wisdom Accumulation and Talent Cultivation Project of the Third Xiangya Hospital of Central South University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aimed to determine the correlation between the intraoperative diameter of double‐stranded peroneus longus tendon (2PLT) and length of the PLT autograft and preoperative ultrasound (US) measurements, as well as radiographic and anthropometric measurements. The hypothesis was that US can accurately predict the diameter of 2PLT autografts during operation.

Methods

Twenty‐six patients underwent ligament reconstruction with 2PLT autografts were included. Preoperative US was used to calculate the in situ PLT cross‐sectional area (CSA) at seven levels (0, 1, 2, 3, 4, 5, 10 cm proximal to the harvest start point). Femoral width, notch width, notch height, maximum patellar length, and patellar tendon length were determined on preoperative radiographs. Intraoperative measurements of PLT were made, including all fiber lengths of PLT and diameters of 2PLT using sizing tubes calibrated to 0.5 mm.

Results

CSA at 1 cm proximal to the harvest site had the highest correlation with the diameter of 2PLT ( r = 0.84, P < 0.001). Calf length had the highest correlation with PLT length ( r = 0.65, P < 0.001). The diameter of the 2PLT autografts could be predicted by the following formula: 4.6 + 0.2 × [sonographic CSA of PLT at 1 cm level]; the length of PLT could be predicted by the following formula: 5.6 + 0.5 × Calf length.

Conclusion

The diameter of 2PLT and length of PLT autografts can be accurately predicted by preoperative US and calf length measurements, respectively. Accurate preoperative prediction of the diameter and length of autologous grafts can provide the most suitable and individualized graft for patients. Level of evidence IV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Anterior Cruciate Ligament ReconstructionPatellar LigamentAnterior Cruciate Ligament InjuriesHumansAutograftsTendonsTransplantation, Autologous

Stichwörter der Autor:innen

AnthropometryLigament reconstructionPeroneus longus tendonRadiological measurementUltrasound

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China.
  • Department of Orthopaedic Surgery, University of Pittsburgh Medical Center, Pittsburgh, PA, 15213, USA.
  • Department of Anesthesiology, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China.
  • School of Mathematics and Statistics, Central South University, Changsha, 410083, Hunan, China.
  • Department of Orthopaedic Surgery, Third Xiangya Hospital of Central South University, Changsha, 410013, Hunan, China. jinshen.he@hotmail.com.

Förderung

  • The Wisdom Accumulation and Talent Cultivation Project of the Third Xiangya Hospital of Central South University

Zitieren

APA

Luo, J., Wu, S., Rothrauff, B., Liao, Q., Feng, J., Tan, L., Cao, Y., Liang, J., Wang, J., & He, J. (2023). Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-023-07406-y

Vancouver

Luo J, Wu S, Rothrauff B, Liao Q, Feng J, Tan L, et al. Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts. Knee Surgery, Sports Traumatology, Arthroscopy. 2023. doi:10.1007/s00167-023-07406-y

BibTeX
@article{Luo2023,
  author = {Luo, Jiewen and Wu, Song and Rothrauff, Benjamin and Liao, Qin and Feng, Jing and Tan, Lingjie and Cao, Yangbo and Liang, Jiehui and Wang, Jiaoju and He, Jinshen},
  title = {Preoperative ultrasound can accurately predict the diameter of double‐stranded peroneus longus tendon autografts},
  journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
  year = {2023},
  doi = {10.1007/s00167-023-07406-y}
}
Kostenlos starten →