Fachartikel in der Zeitschrift Knee Surgery, Sports Traumatology, Arthroscopy, 2022-04. Verfasst von Stefan M Zimmermann und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland. St.zimmermann@gmx.ch. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Knee. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 38 Literaturangaben.
Abstract (Originalsprache)
Purpose
Anterior knee pain (AKP) is common following total knee arthroplasty. The tibial tuberosity trochlear groove distance (TTTG) influences patellofemoral joint loading in the native knee. Increased TTTG may lead to maltracking of the patella and anterior knee pain. The purpose of this study was to investigate potential changes in TTTG following total knee arthroplasty (TKA).
Methods
TTTG was measured on preoperative CT data on a consecutive series of patients scheduled to receive TKA with patient‐specific instrumentation, and compared to a computer simulation of the postoperative TTTG. Preoperative TTTG was measured with a 3D planning software in 250 knees. The postoperative result was simulated and TTTG measured within the software. Three different groups were analysed: neutral (180° ± 3) ( n = 50), valgus (> 190°) ( n = 100), and varus (< 170°) ( n = 100).
Results
Median preoperative to simulated postoperative TTTG decreased from 15.0 [interquartile range (IQR) 6.0] mm to 6.5 (IQR 5.0) mm for all axes combined. A significant postoperative reduction of TTTG was found in each group ( p < 0.001). The mean change in TTTG did not differ significantly between the groups [− 8.8 (IQR 5.5) mm neutral, − 8.3 (IQR 7.0) mm valgus, − 7.5 (IQR 5.8) mm varus, p = 0.223].
Conclusion
This computer‐based study suggests that mechanically aligned TKA significantly decreases TTTG distance in neutral, valgus and varus knees, assuming that the postoperative result coincides with the preoperative planning. Further study is warranted to evaluate the clinical relevance of this finding.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedics, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland. St.zimmermann@gmx.ch.
- Faculty of Medicine, University of Zurich, Zurich, Switzerland. St.zimmermann@gmx.ch.
- Faculty of Medicine, University of Zurich, Zurich, Switzerland.
- Department of Orthopaedics, Balgrist University Hospital, Forchstrasse 340, 8008, Zurich, Switzerland.
Zitieren
APA
Zimmermann, S. M., Scherrer, Y., Zaleski, M., Jentzsch, T., & Fucentese, S. F. (2023). Decrease of tibial tuberosity trochlear groove distance following mechanically aligned total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy, 31(3), 1162-1167. https://doi.org/10.1007/s00167-022-06952-1
Vancouver
Zimmermann SM, Scherrer Y, Zaleski M, Jentzsch T, Fucentese SF. Decrease of tibial tuberosity trochlear groove distance following mechanically aligned total knee arthroplasty. Knee Surgery, Sports Traumatology, Arthroscopy. 2023;31(3):1162-1167. doi:10.1007/s00167-022-06952-1
BibTeX
@article{Zimmermann2023,
author = {Zimmermann, Stefan M and Scherrer, Yves and Zaleski, Martin and Jentzsch, Thorsten and Fucentese, Sandro F},
title = {Decrease of tibial tuberosity trochlear groove distance following mechanically aligned total knee arthroplasty},
journal = {Knee Surgery, Sports Traumatology, Arthroscopy},
year = {2023},
volume = {31},
number = {3},
pages = {1162--1167},
doi = {10.1007/s00167-022-06952-1}
}
EUVIMED