EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische StudieVergleichsstudie

The comparison of circuit lifespan between integration and separation approach in extracorporeal membrane oxygenation patients requiring continuous renal replacement therapy support: a randomized controlled trial (E-CRRT Trial)

Prasittiporn Tangjitaree, Peerapat Thanapongsatorn, Tanyapim Sinjira, Ekkapong Surinrat, Pongpon Suttiruk, Nattachai Srisawat iD

Intensive Care Medicine · 2026-03 · 52 (3) · 434-444

DOI: 10.1007/s00134-026-08302-y ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Intensive Care Medicine, online erschienen am 05.02.2026. Verfasst von Prasittiporn Tangjitaree und 5 weiteren Autor:innen. Beteiligte Einrichtung: Excellence Center for Critical Care Nephrology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Continuous Renal Replacement Therapy, Acute Kidney Injury, Renal Replacement Therapy. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: The estimated incidence of acute kidney injury requiring renal replacement therapy (RRT), mainly continuous RRT (CRRT), in patients necessitating extracorporeal membrane oxygenation (ECMO) is approximately 50%. Currently, two well-known techniques, integration and separation, are utilized for combining CRRT and ECMO circuits, neither of which is considered a standard treatment. PURPOSE: This study aimed to compare circuit lifespan of CRRT between these two techniques during ECMO support. METHODS: A multicentered randomized controlled trial was conducted from May 2021 to March 2025. ECMO patients who required CRRT support were enrolled. Primary outcome was CRRT circuit lifespan. RESULTS: Eighty patients were recruited, with 40 allocated to the integration group and 40 to the separation group. Median circuit lifespan did not significantly differ between the groups (72 h [IQR 45-96.5] vs. 71 h [IQR 45-84]; p = 0.52). Twenty-eight-day mortality rates were also comparable (32.5% vs. 35%; p = 0.81). No significant differences were observed in the incidence of serious adverse events, including air embolism. Transmembrane pressure and CRRT machine alarm frequencies were similar between groups. CONCLUSION: Among critically ill ECMO patients receiving CRRT, there is no significant difference in filter lifespan and serious adverse events between integrating the CRRT circuit into the ECMO circuit and using a separate circuit. TRIAL REGISTRATION: NCT05036616.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracorporeal Membrane OxygenationContinuous Renal Replacement TherapyAcute Kidney InjuryRenal Replacement TherapyHumansFemaleMaleMiddle AgedAdult

Stichwörter der Autor:innen

CRRTCircuitCombinationECMOIntegration

Autor:innen und Institutionen

  • Excellence Center for Critical Care Nephrology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Division of Critical Care Medicine, Department of Anesthesiology, Faculty of Medicine, Chulalongkorn University, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
  • Division of Nephrology, Department of Medicine, Faculty of Medicine , Thammasat University Hospital, Pathum Thani, Thailand.
  • Department of Medicine, Central Chest Institute of Thailand, Nonthaburi, Thailand.
  • Renal Unit, Mongkutwattana Hospital, Bangkok, Thailand.
  • Excellence Center for Critical Care Nephrology, King Chulalongkorn Memorial Hospital, Bangkok, Thailand. nattachai.sr@chula.ac.th.

ORCID-Profile: Nattachai Srisawat

Zitieren

APA

Tangjitaree, P., Thanapongsatorn, P., Sinjira, T., Surinrat, E., Suttiruk, P., & Srisawat, N. (2026). The comparison of circuit lifespan between integration and separation approach in extracorporeal membrane oxygenation patients requiring continuous renal replacement therapy support: a randomized controlled trial (E-CRRT Trial). Intensive Care Medicine, 52(3), 434-444. https://doi.org/10.1007/s00134-026-08302-y

Vancouver

Tangjitaree P, Thanapongsatorn P, Sinjira T, Surinrat E, Suttiruk P, Srisawat N. The comparison of circuit lifespan between integration and separation approach in extracorporeal membrane oxygenation patients requiring continuous renal replacement therapy support: a randomized controlled trial (E-CRRT Trial). Intensive Care Medicine. 2026;52(3):434-444. doi:10.1007/s00134-026-08302-y

BibTeX
@article{Tangjitaree2026,
  author = {Tangjitaree, Prasittiporn and Thanapongsatorn, Peerapat and Sinjira, Tanyapim and Surinrat, Ekkapong and Suttiruk, Pongpon and Srisawat, Nattachai},
  title = {The comparison of circuit lifespan between integration and separation approach in extracorporeal membrane oxygenation patients requiring continuous renal replacement therapy support: a randomized controlled trial (E-CRRT Trial)},
  journal = {Intensive Care Medicine},
  year = {2026},
  volume = {52},
  number = {3},
  pages = {434--444},
  doi = {10.1007/s00134-026-08302-y}
}
Kostenlos starten →