Detection of myeloma-associated osteolytic bone lesions with energy-integrating and photon-counting detector CT
Die Radiologie · 2024
DOI: 10.1007/s00117-024-01344-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Die Radiologie, 2024. Verfasst von Martin Grözinger und 12 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Baden-Württemberg, Germany. Hauptthemen laut MEDLINE: Multiple Myeloma, Tomography, X-Ray Computed, Osteolysis. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
A recent innovation in computed tomography (CT) imaging has been the introduction of photon-counting detector CT (PCD-CT) systems, which are able to register the number and the energy level of incoming x‑ray photons and have smaller detector elements compared with conventional CT scanners that operate with energy-integrating detectors (EID-CT).
Objectives
The study aimed to evaluate the potential benefits of a novel, non-CE certified PCD-CT in detecting myeloma-associated osteolytic bone lesions (OL) compared with a state-of-the-art EID-CT. Materials and methods Nine patients with multiple myeloma stage III (according to Durie and Salmon) underwent magnetic resonance imaging (MRI), EID-CT, and PCD-CT of the lower lumbar spine and pelvis. The PCD-CT and EID-CT images of all myeloma lesions that were visible in clinical MRI scans were reviewed by three radiologists for corresponding OL. Additionally, the visualization of destructions to cancellous or cortical bone, and trabecular structures, was compared between PCD-CT and EID-CT.
Results
Readers detected 21% more OL in PCD-CT than in EID-CT images (138 vs. 109; p < 0.0001). The sensitivity advantage of PCD-CT in lesion detection increased with decreasing lesion size. The visualization quality of cancellous and cortical destructions as well as of trabecular structures was rated higher by all three readers in PCD-CT images (mean image quality improvements for PCD-CT over EID-CT were +0.45 for cancellous and +0.13 for cortical destructions).
Conclusions
For myeloma-associated OL, PCD-CT demonstrated significantly higher sensitivity, especially with small size. Visualization of bone tissue and lesions was considered significantly better in PCD-CT than in EID-CT. This implies that PCD-CT scanners could potentially be used in the early detection of myeloma-associated bone lesions. Graphic abstract
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Radiology, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Baden-Württemberg, Germany.
- Division of X-Ray Imaging and CT, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Baden-Württemberg, Germany.
- Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, 69120, Heidelberg, Baden-Württemberg, Germany.
- Department of Diagnostic and Interventional Radiology, University Hospital of Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
- Department of Medicine V, Multiple Myeloma Section, University Hospital Heidelberg, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
- Division of Biostatistics, German Cancer Research Center, Im Neuenheimer Feld 280, 69120, Heidelberg, Baden-Württemberg, Germany.
Zitieren
APA
Grözinger, M., Wennmann, M., Sawall, S., Wehrse, E., Sedaghat, S., Neelsen, C., Bauer, F., Goldschmidt, H., Weru, V., Ziener, C. H., Kopp-Schneider, A., Schlemmer, H. P., & Rotkopf, L. T. (2024). Detection of myeloma-associated osteolytic bone lesions with energy-integrating and photon-counting detector CT. Die Radiologie. https://doi.org/10.1007/s00117-024-01344-7
Vancouver
Grözinger M, Wennmann M, Sawall S, Wehrse E, Sedaghat S, Neelsen C, et al. Detection of myeloma-associated osteolytic bone lesions with energy-integrating and photon-counting detector CT. Die Radiologie. 2024. doi:10.1007/s00117-024-01344-7
BibTeX
@article{Grzinger2024,
author = {Grözinger, Martin and Wennmann, Markus and Sawall, Stefan and Wehrse, Eckhard and Sedaghat, Sam and Neelsen, Christian and Bauer, Fabian and Goldschmidt, Hartmut and Weru, Vivienn and Ziener, Christian H and Kopp-Schneider, Annette and Schlemmer, Heinz-Peter and Rotkopf, Lukas T},
title = {Detection of myeloma-associated osteolytic bone lesions with energy-integrating and photon-counting detector CT},
journal = {Die Radiologie},
year = {2024},
doi = {10.1007/s00117-024-01344-7}
}
EUVIMED