EUVIMEDEUVIMED entdecken
Crossref

Der ?fehlerhafte? Laborbefund

G M Fiedler, J Thiery

Der Internist · 01.03.2004 · 45 (3) · 315-332

DOI: 10.1007/s00108-003-1126-y ↗

Kurz gefasst

Fachartikel in der Zeitschrift Der Internist, erschienen am 01.03.2004. Verfasst von G M Fiedler und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institut für Laboratoriumsmedizin, Klinische Chemie und Molekulare Diagnostik, Universitätsklinikum Leipzig. Die Arbeit wurde bisher 13-mal zitiert (Crossref).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Laboratory results play a key role in the diagnostic procedure, the decision of treatment and the follow up of diseases. A high validity of the laboratory result is an important precondition for the efficacy in clinical medicine. Analytical standards have been developed under strong quality control criteria, however, there are no sufficiently defined standards for the pre- and postanalytical phase in laboratory diagnostics. Thus, most of laboratory errors are caused by pre- and postanalytical mistakes. The competent knowledge of possible sources for laboratory errors is a critical precondition for their avoidance. Diagnostic sensitivity and specificity play an important role for the choice of a laboratory test, whereas the predictive value should be considered for the medical relevance of the test result. In addition, many interference factors, which may influence the results of the laboratory tests have to be considered as age, sex, race, lifestyle, drugs, pregnancy, specimen collection, quality and handling as well as special factors, which may influence the complex of immunological and molecular diagnostics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Blood Chemical AnalysisCausalityClinical Laboratory TechniquesCross-Sectional StudiesDiagnostic ErrorsDrug InteractionsFemaleGermanyHumansMalePredictive Value of TestsPregnancyQuality Assurance, Health CareRisk FactorsSensitivity and SpecificitySpecimen Handling

Autor:innen und Institutionen

  • Institut für Laboratoriumsmedizin, Klinische Chemie und Molekulare Diagnostik, Universitätsklinikum Leipzig.

Zitieren

APA

Fiedler, G. M., & Thiery, J. (2004). Der ?fehlerhafte? Laborbefund. Der Internist, 45(3), 315-332. https://doi.org/10.1007/s00108-003-1126-y

Vancouver

Fiedler GM, Thiery J. Der ?fehlerhafte? Laborbefund. Der Internist. 2004;45(3):315-332. doi:10.1007/s00108-003-1126-y

BibTeX
@article{Fiedler2004,
  author = {Fiedler, G M and Thiery, J},
  title = {Der ?fehlerhafte? Laborbefund},
  journal = {Der Internist},
  year = {2004},
  volume = {45},
  number = {3},
  pages = {315--332},
  doi = {10.1007/s00108-003-1126-y}
}
Kostenlos starten →