EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improved radiological imaging of congenital aural atresia using flat-panel volume CT

Franz-Tassilo Müller-Graff, Jan von Düring, Johannes Voelker, Fadi Al-Tinawi, Rudolf Hagen, Tilmann Neun, Stephan Hackenberg, Kristen Rak

HNO · 2024

DOI: 10.1007/s00106-024-01512-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift HNO, 2024. Verfasst von Franz-Tassilo Müller-Graff und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of …. Hauptthemen laut MEDLINE: Congenital Abnormalities, Sensitivity and Specificity. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Würzburg.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Precise preoperative radiological evaluation of aural atresia is of utmost importance for surgical planning. Until now, multislice computed tomography (MSCT) has been used but it cannot adequately visualize small structures such as the stapes. Flat-panel volume CT (fpVCT) with its secondary reconstructions (fpVCT SECO ) offers a high-resolution visualization of the middle ear. New otosurgical planning software also enables detailed 3D reconstruction of the middle ear anatomy. Aim of the work Evaluation of the use of fpVCT SECO in combination with an otosurgical planning software for a more accurate diagnosis and treatment of congenital aural atresia. Material and methods Seven patients with congenital aural atresia underwent preoperative MSCT (600 µm slice thickness) and corresponding fpVCT (466 µm slice thickness). In addition, fpVCT SECO (99 µm slice thickness) were reconstructed. The Jahrsdoerfer and Siegert grading scores were determined and their applicability in the abovementioned imaging modalities was evaluated. In addition, the malleus incus complex was analyzed in 3D rendering.

Results

Imaging with fpVCT SECO enabled reliable visualization of the abnormalities, in particular the ossicular chain. A significant difference in the Siegert grading score was found. In addition, the malleus-incus complex could be visualized better in 3D.

Discussion

The introduction of new imaging techniques and surgical planning techniques into the diagnostic concept of aural atresia facilitates the identification of malformed anatomy and enables systematic analysis. This combination can also help to more accurately classify the pathology and thus increase the safety and success of the surgical procedure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Congenital AbnormalitiesSensitivity and SpecificityHumansFemaleMaleReproducibility of ResultsEarAdultImaging, Three-DimensionalRadiographic Image EnhancementCone-Beam Computed TomographySurgery, Computer-AssistedChildYoung Adult

Stichwörter der Autor:innen

Atresia plate and facial nerveComputed-tomography-based softwareEar deformityMiddle ear malformationOTOPLAN

Autor:innen und Institutionen

  • Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Germany. Muelle…
  • Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center, University of Wuerzburg, Josef-Schneider-Straße 11, 97080, Würzburg, Germany.
  • Insitute for Diagnostic and Interventional Neuroradiology, University of Wuerzburg, Würzburg, Germany.

Förderung

  • Universitätsklinikum Würzburg

Zitieren

APA

Müller-Graff, F. T., von Düring, J., Voelker, J., Al-Tinawi, F., Hagen, R., Neun, T., Hackenberg, S., & Rak, K. (2024). Improved radiological imaging of congenital aural atresia using flat-panel volume CT. HNO. https://doi.org/10.1007/s00106-024-01512-0

Vancouver

Müller-Graff FT, von Düring J, Voelker J, Al-Tinawi F, Hagen R, Neun T, et al. Improved radiological imaging of congenital aural atresia using flat-panel volume CT. HNO. 2024. doi:10.1007/s00106-024-01512-0

BibTeX
@article{MllerGraff2024,
  author = {Müller-Graff, Franz-Tassilo and von Düring, Jan and Voelker, Johannes and Al-Tinawi, Fadi and Hagen, Rudolf and Neun, Tilmann and Hackenberg, Stephan and Rak, Kristen},
  title = {Improved radiological imaging of congenital aural atresia using flat-panel volume CT},
  journal = {HNO},
  year = {2024},
  doi = {10.1007/s00106-024-01512-0}
}
Kostenlos starten →