Dynamic parameters of fluid responsiveness in the operating room
Die Anaesthesiologie · 2024
DOI: 10.1007/s00101-024-01428-y ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Die Anaesthesiologie, 2024. Verfasst von M Prütz und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, University Medical Centre Rostock, Schillingallee 35, 18057, Rostock, German…. Hauptthemen laut MEDLINE: Respiration, Artificial, Operating Rooms, Fluid Therapy, Tidal Volume. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsmedizin Rostock.
Abstract (Originalsprache)
Background
Reliable assessment of fluid responsiveness with pulse pressure variation (PPV) depends on certain ventilation-related preconditions; however, some of these requirements are in contrast with recommendations for protective ventilation.
Objective
The aim of this study was to evaluate the applicability of PPV in patients undergoing non-cardiac surgery by retrospectively analyzing intraoperative ventilation data. Material and methods Intraoperative ventilation data from three large medical centers in Germany and Switzerland from January to December 2018 were extracted from electronic patient records and pseudonymized; 10,334 complete data sets were analyzed with respect to the ventilation parameters set as well as demographic and medical data.
Results
In 6.3% of the 3398 included anesthesia records, patients were ventilated with mean tidal volumes (mTV) > 8 ml/kg predicted body weight (PBW). These would qualify for PPV-based hemodynamic assessment, but the majority were ventilated with lower mTVs. In patients who underwent abdominal surgery (75.5% of analyzed cases), mTVs > 8 ml/kg PBW were used in 5.5% of cases, which did not differ between laparoscopic (44.9%) and open (55.1%) approaches. Other obstacles to the use of PPV, such as elevated positive end-expiratory pressure (PEEP) or increased respiratory rate, were also identified. Of all the cases 6.0% were ventilated with a mTV of > 8 ml/kg PBW and a PEEP of 5–10 cmH 2 O and 0.3% were ventilated with a mTV > 8 ml/kg PBW and a PEEP of > 10 cmH 2 O.
Conclusion
The data suggest that only few patients meet the currently defined TV (of > 8 ml/kg PBW) for assessment of fluid responsiveness using PPV during surgery.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, University Medical Centre Rostock, Schillingallee 35, 18057, Rostock, Germany. maria.pruetz@med.uni-rostock.de.
- Department of Anaesthesiology, Intensive Care Medicine and Pain Therapy, University Medical Centre Rostock, Schillingallee 35, 18057, Rostock, Germany.
- The Hirslanden Clinical Trial Unit, Hirslanden AG, Glattpark, Switzerland.
- Institute for Anaesthetics and Intensive Care, Klinik Beau-Site, Hirslanden AG, Bern, Switzerland.
- Department of Anaesthesiology and Surgical Intensive Care, University Medical Centre Schleswig-Holstein, Campus Kiel, Kiel, Germany.
- Department of Anaesthesiology and Critical Care Medicine, University Hospital Carl Gustav Carus and Carl Gustav Carus Faculty of Medicine, TU Dresden, Dresden, Germany.
Förderung
- Universitätsmedizin Rostock
Zitieren
APA
Prütz, M., Bozkurt, A., Löser, B., Haas, S. A., Tschopp, D., Rieder, P., Trachsel, S., Vorderwülbecke, G., Menk, M., Balzer, F., Treskatsch, S., Reuter, D. A., & Zitzmann, A. (2024). Dynamic parameters of fluid responsiveness in the operating room. Die Anaesthesiologie. https://doi.org/10.1007/s00101-024-01428-y
Vancouver
Prütz M, Bozkurt A, Löser B, Haas SA, Tschopp D, Rieder P, et al. Dynamic parameters of fluid responsiveness in the operating room. Die Anaesthesiologie. 2024. doi:10.1007/s00101-024-01428-y
BibTeX
@article{Prtz2024,
author = {Prütz, M and Bozkurt, A and Löser, B and Haas, S A and Tschopp, D and Rieder, P and Trachsel, S and Vorderwülbecke, G and Menk, M and Balzer, F and Treskatsch, S and Reuter, D A and Zitzmann, A},
title = {Dynamic parameters of fluid responsiveness in the operating room},
journal = {Die Anaesthesiologie},
year = {2024},
doi = {10.1007/s00101-024-01428-y}
}
EUVIMED