Fixation of patellar fractures using bioabsorbable hydroxyapatite/poly-L-lactide cannulated screws and subperiosteal nonabsorbable sutures
European Journal of Trauma and Emergency Surgery · 03.11.2026 · 52 (1)
DOI: 10.1007/s00068-026-03373-4 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Trauma and Emergency Surgery, online erschienen am 03.11.2026. Verfasst von Makoto Kobayashi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Nagoya City University Midori Municipal Hospital, 1 -77 Shiomigaoka, Midori-ku, Nagoya, Aichi, 458-0037, Japan. Hauptthemen laut MEDLINE: Patella Fracture, Bone Screws, Absorbable Implants, Fracture Fixation, Internal. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Nagoya City University, Ministry of Education, Culture, Sports, Science, and Technology of Japan.
Abstract (Originalsprache)
Introduction
Bioabsorbable implants offer a promising alternative to metallic fixation for patellar fractures, potentially avoiding hardware-related complications. In 2023, a new generation of bioabsorbable hydroxyapatite/poly-L-lactide (HA/PLLA) cannulated screws was introduced, featuring a low-profile (2 mm) trident-shaped head and increased root diameter for enhanced strength. This study evaluates the clinical outcomes of a surgical technique combining these redesigned screws with subperiosteal nonabsorbable sutures. Materials and methods Between April 2023 and May 2025, 19 consecutive patients with transverse patellar fractures (AO/OTA 34-C1/C2) underwent open reduction and internal fixation. Two bioabsorbable cannulated screws were used. High-strength nonabsorbable sutures were passed through the screw channels and a central bone tunnel using a double-loop sliding knot for compression. The sutures were systematically routed subperiosteally to minimize tissue irritation. Full weight-bearing with a brace began on postoperative day one. Clinical and radiographic outcomes were assessed. This study was approved by the institutional review board of Kainan Hospital.
Results
The mean maximum articular surface gap was 8.7 ± 5.2 mm. The mean follow-up was 8.6 ± 3.0 months. Bone union was achieved in all cases. At the final follow-up, the mean knee flexion was 138.7° ± 13.0° and extension was − 1.6° ± 3.4°. No postoperative complications, including infection, loss of reduction, screw breakage, or symptomatic hardware irritation, were observed during the follow-up period. No reoperations were required during the follow-up period.
Conclusions
All patients achieved bone union. No major complications or reoperations were observed during the follow-up period. These preliminary findings suggest that this technique may be feasible for transverse patellar fractures.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Nagoya City University Midori Municipal Hospital, 1 -77 Shiomigaoka, Midori-ku, Nagoya, Aichi, 458-0037, Japan.
- Department of Orthopaedic Surgery, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi, 467-8601, Japan.
- Department of Orthopaedic Surgery, Aichi Prefectural Welfare Federation of Agricultural Cooperatives Kainan Hospital, 396 Minamihonden, Maegasu-cho, Yatomi, Aichi, 498-8502, Japan.
- Department of Orthopaedic Surgery, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, Aichi, 467-8601, Japan. kokuryugen@yahoo.co.jp.
- Department of Orthopedic Surgery, Nagoya City University Rehabilitation Hospital, 1-2 Mikanyama, Yatomi-cho, Mizuho-ku, Nagoya, 467-8604, Japan. kokuryugen@yahoo.co.jp.
- Department of Orthopaedic Surgery and Rehabilitation Medicine, Nagoya City University Graduate School of Medical Sciences, 1 Kawasumi, Mizuho-cho, Mizuho-ku, Nagoya, 467-8601, Japan. kokuryugen@yahoo.co.jp.
Förderung
- Nagoya City University
- Ministry of Education, Culture, Sports, Science, and Technology of Japan
Zitieren
APA
Kobayashi, M., Usami, T., Takada, N., Iwata, H., Murakami, H., Katsuragawa, R., & Kuroyanagi, G. (2026). Fixation of patellar fractures using bioabsorbable hydroxyapatite/poly-L-lactide cannulated screws and subperiosteal nonabsorbable sutures. European Journal of Trauma and Emergency Surgery, 52(1). https://doi.org/10.1007/s00068-026-03373-4
Vancouver
Kobayashi M, Usami T, Takada N, Iwata H, Murakami H, Katsuragawa R, et al. Fixation of patellar fractures using bioabsorbable hydroxyapatite/poly-L-lactide cannulated screws and subperiosteal nonabsorbable sutures. European Journal of Trauma and Emergency Surgery. 2026;52(1). doi:10.1007/s00068-026-03373-4
BibTeX
@article{Kobayashi2026,
author = {Kobayashi, Makoto and Usami, Takuya and Takada, Naoya and Iwata, Hidetoshi and Murakami, Hideki and Katsuragawa, Riko and Kuroyanagi, Gen},
title = {Fixation of patellar fractures using bioabsorbable hydroxyapatite/poly-L-lactide cannulated screws and subperiosteal nonabsorbable sutures},
journal = {European Journal of Trauma and Emergency Surgery},
year = {2026},
volume = {52},
number = {1},
doi = {10.1007/s00068-026-03373-4}
}
EUVIMED