EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Modified Johannesburg technique sets the standard – superior biomechanical stability in chest tube fixation

Johann Justus Fricke, Tobias Schöbel, Ric Meißner, Stefan Schleifenbaum, Christian Kleber, Isabella Metelmann, Sebastian Krämer

European Journal of Trauma and Emergency Surgery · 22.01.2026 · 52 (1)

DOI: 10.1007/s00068-025-03071-7 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Trauma and Emergency Surgery, online erschienen am 22.01.2026. Verfasst von Johann Justus Fricke und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany. Hauptthemen laut MEDLINE: Chest Tubes, Thoracic Injuries, Suture Techniques. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität Leipzig.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Chest tube dislodgement is a frequent and potentially life-threatening complication after thoracic trauma. Reliable fixation is essential, particularly in emergency and combat casualty care. Several suture techniques exist, but comparative biomechanical evidence is limited.

Methods

This prospective biomechanical cadaveric study compared three fixation techniques—Purse String (PS), Roman Sandal (RS), and Modified Johannesburg (JO) technique —across three tube sizes (20, 24, 28 Charrière) and two materials (polyvinyl chloride (PVC) and silicone). A total of 360 tests were performed on porcine thoracic wall specimens under standardized conditions. Specimens were subjected to vertical load-to-failure testing with continuous measurement of force and elongation.

Results

The Modified Johannesburg technique consistently demonstrated the highest pull-out strength across all tube sizes and materials, significantly outperforming both RS and PS ( p < 0.0001). RS ranked second and showed significantly greater stability than PS in all conditions ( p < 0.0001). Effect size analysis revealed large differences between JO and PS ( r = 0.87) and between RS and PS ( r = 0.50), and a medium effect between JO and RS ( r = 0.36). PVC tubes provided significantly greater pull-out strength than silicone tubes (147.0 ± 54.2 N vs. 128.5 ± 42.2 N; p = 0.01071), although silicone tubes exhibited greater elongation prior to failure. Tube size had a modest influence on stability, with larger tubes tending toward higher pull-out strength, but pairwise differences did not reach significance. The predominant failure mechanism was suture rupture (78.9%), followed by tube rupture (11.1%), knot loosening (8.1%), and skin failure (1.9%).

Conclusions

The Modified Johannesburg Technique offers superior biomechanical stability for chest tube fixation, regardless of tube size or material. This technique should be considered the preferred method in high-risk environments, including military and emergency care, to minimize dislodgement and enhance patient safety.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Chest TubesThoracic InjuriesSuture TechniquesAnimalsBiomechanical PhenomenaSwineCadaverProspective StudiesHumansMaterials Testing

Stichwörter der Autor:innen

BiomechanicsChest tubesCombat careEmergencyFixation techniquesSutureThoracic injuriesTrauma

Autor:innen und Institutionen

  • Department of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany.
  • Department of Orthopedic, Trauma, and Plastic Surgery, University of Leipzig, Liebigstraße 20, 04103, Leipzig, Germany. tobias.schoebel@medizin.uni-leipzig.de.
  • ZESBO - Center for Research on Musculoskeletal Systems, Semmelweisstraße 14, 04103, Leipzig, Germany.
  • Fraunhofer Institute for Machine Tools and Forming Technology, Nöthnitzer Straße 44, 01187, Dresden, Germany.
  • Department of Visceral, Transplantation, Thoracic and Vascular Surgery, Leipzig University, Liebigstraße 20, 04013, Leipzig, Germany.

Förderung

  • Universität Leipzig

Zitieren

APA

Fricke, J. J., Schöbel, T., Meißner, R., Schleifenbaum, S., Kleber, C., Metelmann, I., & Krämer, S. (2026). Modified Johannesburg technique sets the standard – superior biomechanical stability in chest tube fixation. European Journal of Trauma and Emergency Surgery, 52(1). https://doi.org/10.1007/s00068-025-03071-7

Vancouver

Fricke JJ, Schöbel T, Meißner R, Schleifenbaum S, Kleber C, Metelmann I, et al. Modified Johannesburg technique sets the standard – superior biomechanical stability in chest tube fixation. European Journal of Trauma and Emergency Surgery. 2026;52(1). doi:10.1007/s00068-025-03071-7

BibTeX
@article{Fricke2026,
  author = {Fricke, Johann Justus and Schöbel, Tobias and Meißner, Ric and Schleifenbaum, Stefan and Kleber, Christian and Metelmann, Isabella and Krämer, Sebastian},
  title = {Modified Johannesburg technique sets the standard – superior biomechanical stability in chest tube fixation},
  journal = {European Journal of Trauma and Emergency Surgery},
  year = {2026},
  volume = {52},
  number = {1},
  doi = {10.1007/s00068-025-03071-7}
}