Application of CT-based three-dimensional stereotactic localization method in surgery stabilization of rib fractures
European Journal of Trauma and Emergency Surgery · 2026
DOI: 10.1007/s00068-025-03060-w ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Trauma and Emergency Surgery, 2026. Verfasst von Kun Liu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Beijing Shunyi Hospital, Beijing, China. Hauptthemen laut MEDLINE: Rib Fractures, Tomography, X-Ray Computed, Imaging, Three-Dimensional, Fracture Fixation, Internal. Die Arbeit nennt 27 Literaturangaben. Gefördert von: the Scientific Research Development Special Fund of Beijing Shunyi Hospital.
Abstract (Originalsprache)
PURPOSE: This study evaluated the efficacy of computed tomography (CT)-based three-dimensional (3D) stereotactic localization for surgical stabilization of rib fractures (SSRF). METHODS: A retrospective analysis of 54 patients undergoing rib fracture fixation was performed: 33 in the 3D stereotactic localization group and 21 in the conventional intraoperative localization group. Number of fracture sites fixed, number of surgical incisions, use of thoracoscopy, localization accuracy, preoperative Visual Analogue Scale (VAS) score, VAS score on the third postoperative day, delta of VAS scores, surgical field exposure time, intraoperative blood loss, average incision length per plate, drainage volume on the first postoperative day, postoperative hospital stay, and incidence of complications were compared. RESULTS: No statistically significant differences were observed between the two groups in the number of fixed fractures, surgical incisions, VAS scores (preoperative, postoperative, and delta of VAS scores) or incidence of complications. The 3D group exhibited significantly higher localization accuracy (94.21% vs. 75%) and superior perioperative outcomes including shorter exposure time, less blood loss, smaller incision, reduced drainage, and shorter hospital stay. CONCLUSION: The CT-based 3D stereotactic localization method is an effective and valuable technique for SSRF, improving localization accuracy and superior perioperative outcomes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiothoracic Surgery, Beijing Shunyi Hospital, Beijing, China.
- Department of Cardiothoracic Surgery, Beijing Shunyi Hospital, Beijing, China. biantj@163.com.
Förderung
- the Scientific Research Development Special Fund of Beijing Shunyi Hospital
Zitieren
APA
Liu, K., Yin, Q., Li, J., Dong, Z., Hao, J., Liu, J., Ma, Z., & Bian, T. (2026). Application of CT-based three-dimensional stereotactic localization method in surgery stabilization of rib fractures. European Journal of Trauma and Emergency Surgery. https://doi.org/10.1007/s00068-025-03060-w
Vancouver
Liu K, Yin Q, Li J, Dong Z, Hao J, Liu J, et al. Application of CT-based three-dimensional stereotactic localization method in surgery stabilization of rib fractures. European Journal of Trauma and Emergency Surgery. 2026. doi:10.1007/s00068-025-03060-w
BibTeX
@article{Liu2026,
author = {Liu, Kun and Yin, Qiang and Li, Jianshuang and Dong, Zhiyong and Hao, Jun and Liu, Jiang and Ma, Zhikun and Bian, Tiejun},
title = {Application of CT-based three-dimensional stereotactic localization method in surgery stabilization of rib fractures},
journal = {European Journal of Trauma and Emergency Surgery},
year = {2026},
doi = {10.1007/s00068-025-03060-w}
}
EUVIMED