EUVIMEDEUVIMED entdecken
Crossref

Dual-energy CT in diagnosing sacral fractures: assessment of diagnostic accuracy and intra- and inter-rater reliabilities

Takahiro Oda iD, Shimpei Kitada, Hitoshi Hirase, Kenjiro Iwasa, Takahiro Niikura

European Journal of Trauma and Emergency Surgery · 2025

DOI: 10.1007/s00068-024-02673-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Trauma and Emergency Surgery, 2025. Verfasst von Takahiro Oda und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Hyogo Prefectural Nishinomiya Hospital, 13-9, Rokutanji, Nishinomiya, 662-0918, Japan. taka.oda.0116@gmail.com. Hauptthemen laut MEDLINE: Sacrum, Tomography, X-Ray Computed, Spinal Fractures, Radiography, Dual-Energy Scanned Projection. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Evaluating sacral fractures is crucial in fragility fractures of the pelvis. Dual-energy CT (DECT) is considered useful for diagnosing unclear fractures on single-energy CT (SECT). This study aims to investigate the effectiveness of DECT in diagnosing sacral fractures. METHODS: Thirty cases with suspected sacral fractures underwent SECT, DECT, and MRI. The exams were evaluated by two groups: three inexperienced surgeons (Group I) and three experienced surgeons (Group E). Diagnoses were made initially using SECT (pre-DECT) and then reassessed including DECT (post-DECT). This process was repeated twice. Presence of fractures was determined based on MRI. Sensitivity, specificity, inter-rater and intra-rater reliability, and diagnostic accuracy were calculated. Diagnostic accuracy was statistically compared between two groups. RESULTS: Sensitivity was 0.73 in pre-DECT and 0.9 in post-DECT, while specificity was 0.83 in pre-DECT and 0.91 in post-DECT. Sensitivity significantly improved with the addition of DECT (McNemar test: p < 0.001). Intra-rater reliability (Fleiss' kappa coefficient) was 0.44 in pre-DECT and 0.76 in post-DECT. Inter-rater reliability (Cohen's kappa coefficient) was 0.6 in pre-DECT and 0.81 in post-DECT. Diagnostic accuracy was significantly lower in group I than group E in pre-DECT (P = 0.019, 0.048), but there was no significant difference between two groups in post-DECT. CONCLUSION: Combined use of DECT with SECT improved the detection rate of sacral fractures and enhanced intra-rater and inter-rater reliability. High diagnostic accuracy was achieved regardless of the observer's experience. These results indicate that DECT is a useful imaging modality for diagnosing sacral fractures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SacrumTomography, X-Ray ComputedSpinal FracturesRadiography, Dual-Energy Scanned ProjectionHumansFemaleMaleReproducibility of ResultsAgedSensitivity and SpecificityObserver VariationMiddle AgedMagnetic Resonance ImagingAged, 80 and overAdult

Stichwörter der Autor:innen

Dual-energy CTFragility fractures of the pelvisInter-rater reliabilityIntra-rater reliabilitySacral fracture

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Hyogo Prefectural Nishinomiya Hospital, 13-9, Rokutanji, Nishinomiya, 662-0918, Japan. taka.oda.0116@gmail.com.
  • Department of Orthopedic Surgery/Trauma Center, Hyogo Prefectural Nishinomiya Hospital, 13-9, Rokutanji, Nishinomiya, 662-0918, Japan.
  • Department of Orthopaedic Surgery, Hyogo Prefectural Nishinomiya Hospital, 13-9, Rokutanji, Nishinomiya, 662-0918, Japan.

ORCID-Profile: Takahiro Oda

Zitieren

APA

Oda, T., Kitada, S., Hirase, H., Iwasa, K., & Niikura, T. (2025). Dual-energy CT in diagnosing sacral fractures: assessment of diagnostic accuracy and intra- and inter-rater reliabilities. European Journal of Trauma and Emergency Surgery. https://doi.org/10.1007/s00068-024-02673-x

Vancouver

Oda T, Kitada S, Hirase H, Iwasa K, Niikura T. Dual-energy CT in diagnosing sacral fractures: assessment of diagnostic accuracy and intra- and inter-rater reliabilities. European Journal of Trauma and Emergency Surgery. 2025. doi:10.1007/s00068-024-02673-x

BibTeX
@article{Oda2025,
  author = {Oda, Takahiro and Kitada, Shimpei and Hirase, Hitoshi and Iwasa, Kenjiro and Niikura, Takahiro},
  title = {Dual-energy CT in diagnosing sacral fractures: assessment of diagnostic accuracy and intra- and inter-rater reliabilities},
  journal = {European Journal of Trauma and Emergency Surgery},
  year = {2025},
  doi = {10.1007/s00068-024-02673-x}
}
Kostenlos starten →