Clinical and functional outcomes of locked plating vs. cerclage compression wiring for AO type C patellar fractures– a retrospective single-center cohort study
European Journal of Trauma and Emergency Surgery · 2024
DOI: 10.1007/s00068-024-02633-5 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift European Journal of Trauma and Emergency Surgery, 2024. Verfasst von Steven Bickel und 7 weiteren Autor:innen. Beteiligte Einrichtung: Harald-Tscherne Laboratory for Orthopaedic and Trauma Research, University Hospital Zurich, University of Zurich, Ramistr. 100, Zurich, 8091, Switzer…. Hauptthemen laut MEDLINE: Bone Wires, Fracture Fixation, Internal, Bone Plates, Fractures, Bone. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Zurich.
Abstract (Originalsprache)
Purpose
Although “tension-band wiring” is still commonly used to stabilize patellar fractures, the technique has recently been scrutinized due to biomechanical insufficiency. Consequently, the AO Foundation renamed the principle to compression cerclage wiring (CCW). Several studies propose favorable outcomes when utilizing locked plating (LP). This study aims to compare outcome of CCW and LP for complex patellar fractures.
Methods
A retrospective, single-center cohort study was performed on patients who underwent operative treatment for (AO 34 C-Type) patellar fractures between April 2013 and March 2023. Patients with a 12 month follow up were included. We grouped and compared patients based on the applied treatment strategy: group LP vs. group CCW. Primary outcome parameters included implant-related complications and revision surgeries. Secondary outcomes were length of stay, return to work and 12 months functional outcome (Lysholm score). Odd ratios for complications and revisions were calculated using the conditional Maximum Likelihood Estimate. The threshold for statistical significance was set at p < 0.05.
Results
Of 145 patients, 63 could be included (group LP: n = 23 and group CCW: n = 40). Fractures in group LP were significantly more complex in regard to AO Classification ( p < 0.001), number of fragments ( p < 0.001) and degree of comminution ( p < 0.001), yet odds of complications were significantly lower in group LP (OR: 0.147; 95%CI: 0.015–0.742; p = 0.009). K-wire migration was the most common complication in group CCW (20%). Odds of revision surgery were significantly lower in group LP (OR: 0.000; 95%CI: 0.000-1.120; p = 0.041). The average Lysholm score at one year was favorable in both groups (89.8; SD: 11.9 in group LP and 90.6; SD: 9.3 in group CCW; n.s.).
Conclusion
In our study cohort, LP was routinely chosen for more complex fracture morphologies; nevertheless the data implies that LP may be considered as the superior fixation technique in regard to complications and revision operations. Especially, K-wire migration occurs frequently after CCW. The one year functional outcome was comparable between the groups, with both demonstrating good results. Prospective randomized studies are indicated to validate our findings.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Harald-Tscherne Laboratory for Orthopaedic and Trauma Research, University Hospital Zurich, University of Zurich, Ramistr. 100, Zurich, 8091, Switzerland.
- Department of Trauma Surgery, University Hospital Zurich, University of Zurich, Ramistr. 100, Zurich, 8091, Switzerland.
- Department of Trauma Surgery, University Hospital Zurich, University of Zurich, Ramistr. 100, Zurich, 8091, Switzerland. yannik.kalbas@gmail.com.
- Harald-Tscherne Laboratory for Orthopaedic and Trauma Research, University Hospital Zurich, University of Zurich, Ramistr. 100, Zurich, 8091, Switzerland. yannik.kalbas@gmail.com.
Förderung
- University of Zurich
Zitieren
APA
Bickel, S., Jensen, K. O., Klingebiel, F. K., Teuben, M. P. J., Pfeifer, R., Pape, H. C., Hierholzer, C., & Kalbas, Y. (2024). Clinical and functional outcomes of locked plating vs. cerclage compression wiring for AO type C patellar fractures– a retrospective single-center cohort study. European Journal of Trauma and Emergency Surgery. https://doi.org/10.1007/s00068-024-02633-5
Vancouver
Bickel S, Jensen KO, Klingebiel FK, Teuben MPJ, Pfeifer R, Pape HC, et al. Clinical and functional outcomes of locked plating vs. cerclage compression wiring for AO type C patellar fractures– a retrospective single-center cohort study. European Journal of Trauma and Emergency Surgery. 2024. doi:10.1007/s00068-024-02633-5
BibTeX
@article{Bickel2024,
author = {Bickel, Steven and Jensen, Kai Oliver and Klingebiel, Felix Karl-Ludwig and Teuben, Michel Paul Johan and Pfeifer, Roman and Pape, Hans-Christoph and Hierholzer, Christian and Kalbas, Yannik},
title = {Clinical and functional outcomes of locked plating vs. cerclage compression wiring for AO type C patellar fractures– a retrospective single-center cohort study},
journal = {European Journal of Trauma and Emergency Surgery},
year = {2024},
doi = {10.1007/s00068-024-02633-5}
}
EUVIMED