Swarm Learning for the Detection of Middle Cerebral Artery Occlusion On CT Angiography
Clinical Neuroradiology · 08.07.2026
DOI: 10.1007/s00062-026-01697-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Clinical Neuroradiology, online erschienen am 08.07.2026. Verfasst von Julia K Harten und 14 weiteren Autor:innen. Beteiligte Einrichtung: University Hospital Bonn, Clinic of Neuroradiology, University of Bonn, Bonn, Germany. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Rheinische Friedrich-Wilhelms-Universität Bonn.
Abstract (Originalsprache)
Purpose
Swarm Learning has been introduced as a decentralized alternative to Central Learning. We aimed to evaluate whether Swarm Learning (SL) is equivalent to Central Learning (CL) for training AI models to detect middle cerebral artery (MCA) occlusions on CT angiography (CTA).
Methods
This retrospective study included CTAs of patients suspected of ischemic stroke and negative controls from two institutions and three scanners between October 2010 and March 2024. After manual segmentation of occluded vessels by two raters, two AI algorithms (MedNeXt‑S, Swin UNETR) were trained using CL and SL. Sensitivity, specificity, positive/negative predictive values (PPV, NPV), accuracy, and AUC were calculated. Significance testing was performed using the exact McNemar test and comparisons of relative predictive values. For external validation, CTAs from a fourth scanner from a third institution were used.
Results
470 CTAs of 470 patients (mean age, 72.6 years ±14.3; 247 women) were included, with 356 (75.7%) MCA-occlusions. Training used 375–377 CTAs (79.8–80.2%), with 93–95 (19.8–20.2%) for internal validation. For internal validation, averaged accuracy ranged from 87.23–92.54%, sensitivity from 91.13–93.56%, specificity from 64.82–95.92%, PPV from 90.27–98.44%, and NPV from 73.39–78.66%. For external validation, 101 CTAs of 101 patients (mean age 70.9 years ±16.8; 56 women) were included, with 27 CTAs (26.7%) showing MCA occlusion. Neither internal nor external validation showed significant differences between SL and CL.
Conclusion
AI models trained with SL showed no significant differences compared with CL and may represent a sustainable, and data-safe alternative.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University Hospital Bonn, Clinic of Neuroradiology, University of Bonn, Bonn, Germany.
- Institute for Applied Mathematics, University of Bonn, Bonn, Germany.
- University Hospital Bonn, Department of Radiology, University of Bonn, Bonn, Germany.
- Department of Neurology, Kamillus Klinik, Asbach, Germany.
- University Hospital Bonn, Center for Neurology, Department for Vascular Neurology, University of Bonn, Bonn, Germany.
- Systems Medicine, German Center for Neurodegenerative Diseases, Bonn, Germany.
Förderung
- Rheinische Friedrich-Wilhelms-Universität Bonn
Zitieren
APA
Harten, J. K., Hansel, S., Creuzberg, D., Brugnara, G., Kuetting, D., Uebachs, M., Weller, J., Petzold, G. C., Dorn, F., Vollmuth, P., Aschenbrenner, A. C., Schultze, J. L., Radbruch, A., Effland, A., & Lehnen, N. C. (2026). Swarm Learning for the Detection of Middle Cerebral Artery Occlusion On CT Angiography. Clinical Neuroradiology. https://doi.org/10.1007/s00062-026-01697-7
Vancouver
Harten JK, Hansel S, Creuzberg D, Brugnara G, Kuetting D, Uebachs M, et al. Swarm Learning for the Detection of Middle Cerebral Artery Occlusion On CT Angiography. Clinical Neuroradiology. 2026. doi:10.1007/s00062-026-01697-7
BibTeX
@article{Harten2026,
author = {Harten, Julia K and Hansel, Soma and Creuzberg, Dominik and Brugnara, Gianluca and Kuetting, Daniel and Uebachs, Mischa and Weller, Johannes and Petzold, Gabor C and Dorn, Franziska and Vollmuth, Philipp and Aschenbrenner, Anna C and Schultze, Joachim L and Radbruch, Alexander and Effland, Alexander and Lehnen, Nils C},
title = {Swarm Learning for the Detection of Middle Cerebral Artery Occlusion On CT Angiography},
journal = {Clinical Neuroradiology},
year = {2026},
doi = {10.1007/s00062-026-01697-7}
}
EUVIMED