EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Effect of thermomechanical aging on force system of orthodontic aligners made of different thermoformed materials

Tarek M Elshazly, Ludger Keilig, Diva Nang, Bijan Golkhani, Anna Weber, Hanaa Elattar, Sameh Talaat, Christoph Bourauel

Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · 2025-09 · 86 (5) · 337-346

DOI: 10.1007/s00056-024-00527-0 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, online erschienen am 23.04.2024. Verfasst von Tarek M Elshazly und 7 weiteren Autor:innen. Beteiligte Einrichtung: Oral Technology Department, Dental School, University Hospital Bonn, Bonn, Germany. tarek.m.elshazly@gmail.com. Hauptthemen laut MEDLINE: Orthodontic Appliances, Removable, Orthodontic Appliance Design, Dental Stress Analysis, Tooth Movement Techniques. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universitätsklinikum Bonn.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim was to investigate the effect of aging by thermocycling and mechanical loading on forces and moments generated by orthodontic clear aligners made from different thermoplastic materials.

Methods

A total of 25 thermoformed aligners made from 5 different materials, i.e., Essix ACE® and Essix® PLUS™ (Dentsply Sirona, Bensheim, Germany), Invisalign® (Align Technology, San Jose, CA, USA), Duran®+ (Iserlohn, Germany), Zendura™ (Fremont, CA, USA), underwent a 14-day aging protocol involving mechanical loading (a 0.2 mm vestibular malalignment of the upper left second premolar [tooth 25]) and thermocycling in deionized water (temperature range 5–55 °C). The 3D forces/moments exerted on tooth 25 of a resin model were measured at three time points: before aging (day 0), after 2 days and after 14 days of aging.

Results

Before aging, extrusion–intrusion forces were 0.6–3.0 N, orovestibular forces were 1.7–2.3 N, and moments as mesiodistal rotation were 0.3–42.1 Nmm. In all directions, multilayer Invisalign® exhibited the lowest force/moment magnitudes. After aging, all materials showed a significant force/moment decay within the first 2 days, except Invisalign® for orovestibular and vertical translation. However, following thermomechanical aging, Duran®+ and Zendura™ aligners had equivalent or even higher vestibular forces (direction of mechanical load).

Conclusion

Thermomechanical aging significantly reduced forces and moments during the first 48 h. Multilayer aligner materials exhibit lower initial forces and moments than single-layer ones, and were less influenced by aging. Material hardening was observed after subjecting some of the aligner materials to mechanical loading. Thus, orthodontists should be aware of possible deterioration of orthodontic aligners over time. This work also sheds light on how material selection impacts the mechanical behavior of aligners and may provide valuable guidance regarding optimal timing for the aligner changing protocol.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthodontic Appliances, RemovableOrthodontic Appliance DesignDental Stress AnalysisTooth Movement TechniquesMaterials TestingHumansStress, MechanicalIn Vitro Techniques

Stichwörter der Autor:innen

BiomechanicsClear aligner appliancesOrthodontic forcesTooth movementTorque

Autor:innen und Institutionen

  • Oral Technology Department, Dental School, University Hospital Bonn, Bonn, Germany. tarek.m.elshazly@gmail.com.
  • Oral Technology, University Hospital Bonn, Welschnonnenstr. 17, 53111, Bonn, Germany. tarek.m.elshazly@gmail.com.
  • Oral Technology Department, Dental School, University Hospital Bonn, Bonn, Germany.
  • Department of Dental Prosthetics, Propaedeutics and Materials Science, Dental School, University Hospital Bonn, Bonn, Germany.
  • Orthodontic Department, Faculty of Dentistry, Umm Al-Qura University, Makkah, Saudi Arabia.
  • Orthodontic Department, Faculty of Dentistry, Suez Canal University, Ismailia, Egypt.

Förderung

  • Universitätsklinikum Bonn

Zitieren

APA

Elshazly, T. M., Keilig, L., Nang, D., Golkhani, B., Weber, A., Elattar, H., Talaat, S., & Bourauel, C. (2025). Effect of thermomechanical aging on force system of orthodontic aligners made of different thermoformed materials. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 86(5), 337-346. https://doi.org/10.1007/s00056-024-00527-0

Vancouver

Elshazly TM, Keilig L, Nang D, Golkhani B, Weber A, Elattar H, et al. Effect of thermomechanical aging on force system of orthodontic aligners made of different thermoformed materials. Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie. 2025;86(5):337-346. doi:10.1007/s00056-024-00527-0

BibTeX
@article{Elshazly2025,
  author = {Elshazly, Tarek M and Keilig, Ludger and Nang, Diva and Golkhani, Bijan and Weber, Anna and Elattar, Hanaa and Talaat, Sameh and Bourauel, Christoph},
  title = {Effect of thermomechanical aging on force system of orthodontic aligners made of different thermoformed materials},
  journal = {Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie},
  year = {2025},
  volume = {86},
  number = {5},
  pages = {337--346},
  doi = {10.1007/s00056-024-00527-0}
}
Kostenlos starten →