The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series ( N10 ‐ N150 )
X-Ray Spectrometry · 25.05.2026
DOI: 10.1002/xrs.70119 ↗Kurz gefasst
Fachartikel in der Zeitschrift X-Ray Spectrometry, online erschienen am 25.05.2026. Verfasst von Matheus Rebello do Nascimento und 4 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Conselho Nacional de Desenvolvimento Científico e Tecnológico, Comissão Nacional de Energia Nuclear, Coordenação de Aperfeiçoamento de Pessoal de Nível Superior.
Abstract (Originalsprache)
Spectrometry is an important tool for the characterization of X‐ray beams in ionizing radiation metrology. However, the use of solid‐state spectrometers for accurate measurements requires correction of spectral distortions caused by the interaction between photons and the detector. In this sense, the Stripping methodology was used to correct these distortions and validate the method for the ISO 4037‐1 narrow spectra series, from qualities N10 to N150, measured with an Amptek CdTe spectrometer. This method was implemented in Python 3, and its performance was evaluated quantitatively through the ISO mean energy and spectral resolution requirements, and qualitatively through the spectral shape. Monte Carlo simulations of the pulse‐height distribution were performed for the N120 and N150 spectra using EGSnrc to investigate the influence of the manufacturer's collimator on the measurements. It was observed that the differences between the quantitative parameters of the corrected spectra are within the standard tolerance, except for N120 and N150, for which the shape, mean energy, and spectral resolution are significantly different, with errors of 5% and 9%, and 11% and 22%, respectively. These results suggest that the Stripping method reduces spectral distortion and is therefore suitable for correcting N10–N100 radiation qualities with a CdTe spectrometer. The divergences found for N120 and N150 are therefore related to the manufacturer's collimator, since its thickness does not properly shield these beams. New studies should therefore be conducted to develop an improved design, as suggested by the simulations.
Förderung
- Conselho Nacional de Desenvolvimento Científico e Tecnológico
- Comissão Nacional de Energia Nuclear
- Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Zitieren
APA
Nascimento, M. R. D., Santos, J. C., Macedo, E. M., Pacífico, L. D. C., & Magalhães, L. A. G. (2026). The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series ( N10 ‐ N150 ). X-Ray Spectrometry. https://doi.org/10.1002/xrs.70119
Vancouver
Nascimento MRD, Santos JC, Macedo EM, Pacífico LDC, Magalhães LAG. The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series ( N10 ‐ N150 ). X-Ray Spectrometry. 2026. doi:10.1002/xrs.70119
BibTeX
@article{Nascimento2026,
author = {Nascimento, Matheus Rebello do and Santos, Josilene Cerqueria and Macedo, Eric Matos and Pacífico, Leonardo de Castro and Magalhães, Luís Alexandre Gonçalves},
title = {The Stripping Method for X‐Ray Spectral Correction in ISO 4037‐1 Narrow Spectra Series ( N10 ‐ N150 )},
journal = {X-Ray Spectrometry},
year = {2026},
doi = {10.1002/xrs.70119}
}
EUVIMED