EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Influence of camera model and alignment on the performance of paired camera stations

Tim C. Swearingen, Robert W. Klaver, Charles R. Anderson, Christopher N. Jacques

Wildlife Society Bulletin · 2023-06 · 47 (2)

DOI: 10.1002/wsb.1422 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Wildlife Society Bulletin, online erschienen am 10.01.2023. Verfasst von Tim C. Swearingen und 3 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 81 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Illinois Department of Natural Resources.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The probability of obtaining images of target species may vary across camera models or relative position of cameras at survey locations. Alignment of cameras within paired camera stations (hereafter, stations) could affect species detection due to issues with image exposure. We quantified effects of 3 camera models and alignment (staggered, offset by a perpendicular distance of 4.6 m, and aligned, directly facing one another) on camera performance in a station design. Mean exposure events (flash from one camera overexposes or underexposes pictures) at aligned stations was 3.93 (SE = 1.01; n = 40), whereas no exposure events were documented at staggered ( n = 36) stations. Overall frequency of exposure events of mammal images at aligned cameras was 44% (68 exposure events/153 images). On average, 8% (range 0−35%) of mammal images from aligned stations were exposure events. We detected no difference ( P = 0.88) in exposure events among paired camera models. Further, we detected no overall differences ( P ≥ 0.07) in paired camera performance (i.e., number of mammal images over survey interval) between aligned or staggered stations, though reliability (i.e., percentage of camera stations that lasted entire survey interval) varied ( P ≤ 0.001) between model types. Research deploying 2 cameras within a camera station framework can eliminate exposure events by using a staggered camera alignment without affecting the number of usable mammal photos. Rigorous field testing prior to deployment of stations is warranted to optimize reliability. One of our low‐cost models performed as well as a more expensive model within our paired camera stations at collecting mammal images, and thus could be incorporated into study designs without compromising quality of camera photo data. We suggest a pilot study before large‐scale deployment to evaluate reliability and performance of cameras, particularly when deploying multiple models.

Förderung

  • Illinois Department of Natural Resources

Zitieren

APA

Swearingen, T. C., Klaver, R. W., Anderson, C. R., & Jacques, C. N. (2023). Influence of camera model and alignment on the performance of paired camera stations. Wildlife Society Bulletin, 47(2). https://doi.org/10.1002/wsb.1422

Vancouver

Swearingen TC, Klaver RW, Anderson CR, Jacques CN. Influence of camera model and alignment on the performance of paired camera stations. Wildlife Society Bulletin. 2023;47(2). doi:10.1002/wsb.1422

BibTeX
@article{Swearingen2023,
  author = {Swearingen, Tim C. and Klaver, Robert W. and Anderson, Charles R. and Jacques, Christopher N.},
  title = {Influence of camera model and alignment on the performance of paired camera stations},
  journal = {Wildlife Society Bulletin},
  year = {2023},
  volume = {47},
  number = {2},
  doi = {10.1002/wsb.1422}
}
Kostenlos starten →