EUVIMEDEUVIMED entdecken
Crossref

Trocar‐site incisional hernia after 8‐mm robotic trocar placement: A prospective study

Agnese Cianfarani, Francesco Mongelli iD, Fabiano Iaquinandi, Genti Xhepa, Ramon Pini, Paolo Gaffuri, Davide La Regina

World Journal of Surgery · 2024

DOI: 10.1002/wjs.12214 ↗

Kurz gefasst

Fachartikel in der Zeitschrift World Journal of Surgery, 2024. Verfasst von Agnese Cianfarani und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Lugano Regional Hospital, EOC, Lugano, Switzerland. Hauptthemen laut MEDLINE: Incisional Hernia, Robotic Surgical Procedures, Surgical Instruments. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The current literature supports the closure of trocar sites ≥10‐mm for the risk of developing incisional hernias, while there is no need to suture the abdominal fascia when using 5‐mm trocars. To date, evidence regarding the closure of 8‐mm trocars that are use by new robotic systems is weak. The aim of our study was to investigate the incidence of incisional hernia for 8‐mm trocars.

Methods

We prospectively collected data on all patients undergoing robotic‐assisted abdominal wall surgery from 2020 to 2023, in whom the abdominal fascia of all 8‐mm trocars was not closed. The enrolled patients underwent a follow‐up visit during which we conducted clinical and sonographic evaluations of all 8‐mm trocars, in addition to assessing the satisfaction levels of the patients. The primary outcome was the incidence of port‐site hernia.

Results

We enrolled 166 patients, 155 men and 11 women, for a total of 513 trocars accessed. Mean age was 61.1 ± 14.0 years, and mean BMI was 27.0 ± 3.9 kg/m 2 . The follow‐up visits were carried out after a median follow‐up of 14.5 (9.0–23.2) months. Only one case developed an asymptomatic 1 × 1 cm supra‐umbilical hernia that was not treated. Patient reported a satisfaction regarding the 8‐mm trocars and skin sutures of 9.8 ± 0.5 out of 10 points.

Conclusions

The occurrence of a trocar‐site hernia after 8‐mm robotic access is extremely low. Hence, the fascia closure may not be necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Incisional HerniaRobotic Surgical ProceduresSurgical InstrumentsHumansMaleFemaleProspective StudiesMiddle AgedAgedIncidenceAbdominal WallAdultEquipment Design

Stichwörter der Autor:innen

incisional herniainguinal hernialaparoscopyrobotic surgerytrocartrocar‐site

Autor:innen und Institutionen

  • Department of Surgery, Lugano Regional Hospital, EOC, Lugano, Switzerland.
  • Department of Surgery, Bellinzona e Valli Regional Hospital, EOC, Bellinzona, Switzerland.
  • Faculty of Biomedical Sciences, Università della Svizzera Italiana, Lugano, Switzerland.

ORCID-Profile: Francesco Mongelli

Zitieren

APA

Cianfarani, A., Mongelli, F., Iaquinandi, F., Xhepa, G., Pini, R., Gaffuri, P., & La Regina, D. (2024). Trocar‐site incisional hernia after 8‐mm robotic trocar placement: A prospective study. World Journal of Surgery. https://doi.org/10.1002/wjs.12214

Vancouver

Cianfarani A, Mongelli F, Iaquinandi F, Xhepa G, Pini R, Gaffuri P, et al. Trocar‐site incisional hernia after 8‐mm robotic trocar placement: A prospective study. World Journal of Surgery. 2024. doi:10.1002/wjs.12214

BibTeX
@article{Cianfarani2024,
  author = {Cianfarani, Agnese and Mongelli, Francesco and Iaquinandi, Fabiano and Xhepa, Genti and Pini, Ramon and Gaffuri, Paolo and La Regina, Davide},
  title = {Trocar‐site incisional hernia after 8‐mm robotic trocar placement: A prospective study},
  journal = {World Journal of Surgery},
  year = {2024},
  doi = {10.1002/wjs.12214}
}
Kostenlos starten →