Technical details of robotic pancreatojejunostomy using a modified Blumgart anastomosis: Thread manipulation using gauze and an assisted port
World Journal of Surgery · 2024
DOI: 10.1002/wjs.12208 ↗Kurz gefasst
Fachartikel in der Zeitschrift World Journal of Surgery, 2024. Verfasst von Yuichiro Uchida und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Surgery, Fujita Health University, Toyoake, Japan. Hauptthemen laut MEDLINE: Robotic Surgical Procedures, Pancreaticojejunostomy, Pancreaticoduodenectomy. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
Backgrounds Pancreatojejunostomy is a technically demanding procedure during robotic pancreaticoduodenectomy (RPD). Modified Blumgart anastomosis (mBA) is a common method for the pancreatojejunostomy; however, the technical details for robotic mBA are not well established. During RPD, we performed a mBA for the pancreatojejunostomy using thread manipulation with gauze and an additional assist port.
Methods
Patients who underwent robotic pancreatoduodenectomy at Fujita Health University from November 2009 to May 2023 were retrospectively investigated, and technical details for the robotic‐modified Blumgart anastomosis were demonstrated.
Results
Among 78 patients who underwent RPD during the study period, 33 underwent robotic mBA. Postoperative pancreatic fistula (POPF) occurred in six patients (18%). None of the patients suffered POPF Grade C according to the international study group of pancreatic surgery definition. The anastomotic time for mBA was 80 min (54–125 min).
Conclusion
Robotic mBA resulted in reasonable outcomes. We propose that mBA could be used as one of the standard methods for robotic pancreatojejunosotomy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Surgery, Fujita Health University, Toyoake, Japan.
- Department of Advanced Laparoscopic and Robotic Surgery, Fujita Health University, Toyoake, Japan.
ORCID-Profile: Yuichiro Uchida
Zitieren
APA
Uchida, Y., Takahara, T., Mizumoto, T., Nishimura, A., Mii, S., Iwama, H., Kojima, M., Kato, Y., Uyama, I., & Suda, K. (2024). Technical details of robotic pancreatojejunostomy using a modified Blumgart anastomosis: Thread manipulation using gauze and an assisted port. World Journal of Surgery. https://doi.org/10.1002/wjs.12208
Vancouver
Uchida Y, Takahara T, Mizumoto T, Nishimura A, Mii S, Iwama H, et al. Technical details of robotic pancreatojejunostomy using a modified Blumgart anastomosis: Thread manipulation using gauze and an assisted port. World Journal of Surgery. 2024. doi:10.1002/wjs.12208
BibTeX
@article{Uchida2024,
author = {Uchida, Yuichiro and Takahara, Takeshi and Mizumoto, Takuya and Nishimura, Akihiro and Mii, Satoshi and Iwama, Hideaki and Kojima, Masayuki and Kato, Yutaro and Uyama, Ichiro and Suda, Koichi},
title = {Technical details of robotic pancreatojejunostomy using a modified Blumgart anastomosis: Thread manipulation using gauze and an assisted port},
journal = {World Journal of Surgery},
year = {2024},
doi = {10.1002/wjs.12208}
}
EUVIMED