PFAS Removal During Pyrolysis of Biosolids Is Affected by Initial PFAS Concentration and Pyrolysis Efficiency
Water Environment Research · 2026-04 · 98 (4)
DOI: 10.1002/wer.70352 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water Environment Research, online erschienen am 07.04.2026. Verfasst von Patrick J McNamara und 8 weiteren Autor:innen. Beteiligte Einrichtung: Black & Veatch, Milwaukee, Wisconsin, USA. Hauptthemen laut MEDLINE: Pyrolysis, Fluorocarbons, Biosolids, Water Pollutants, Chemical. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 79 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Water Research Foundation.
Abstract (Originalsprache)
Current and pending biosolids regulations related to per‐ and polyfluoroalkyl substances (PFAS) have triggered the industry to consider emerging biosolids treatment processes. Thermal processes, in particular, have garnered interest for their potential to remove PFAS from the solid phase. Research has documented that pyrolysis can remove PFAS from the solid phase at PFAS concentrations found in non‐industrially impacted biosolids, but little information is available on the fate of PFAS in effluent py‐liquid and py‐gas phases. The objective of this research was to determine the fate of PFAS during pyrolysis of biosolids using non‐industrially impacted and industrially impacted biosolids. Bench‐scale pyrolysis experiments were conducted in triplicate at 500°C and 800°C. PFAS were quantified in the resulting biochar, py‐liquid, and py‐gas. PFAS removal was greater than 95% at both temperatures for the non‐industrially impacted biosolids, but removal was 24%–88% in the industrially impacted biosolids at 500°C. At 800°C, removal was over 95% as well for the industrially impacted biosolids. The biochar yield was highest for the industrially impacted biosolids at 500°C, indicating less conversion of solids to liquid/gas and that the extent of pyrolysis reaction, in addition to initial PFAS concentration, can impact PFAS removal. The mass of PFAS in the effluent liquid and gas for the non‐industrially impacted biosolids was approximately half of the influent PFAS mass, suggesting that a substantial fraction of PFAS is transferred/transformed in the effluent liquid and gas products that would require further polishing for improved PFAS removal.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Black & Veatch, Milwaukee, Wisconsin, USA.
- Civil, Construction & Environmental Engineering, Marquette University, Milwaukee, Wisconsin, USA.
- Eurofins Environment Testing USA, Sacramento, California, USA.
- Eurofins Environment Testing USA, Knoxville, Tennessee, USA.
- California State University-Bakersfield, Bakersfield, California, USA.
Förderung
- Water Research Foundation
Zitieren
APA
McNamara, P. J., Calteux, J., Redman, E., Adkins, C., McKnight, T., Moss, L., Ayala, R., Ishida, S., & Liu, Z. (2026). PFAS Removal During Pyrolysis of Biosolids Is Affected by Initial PFAS Concentration and Pyrolysis Efficiency. Water Environment Research, 98(4). https://doi.org/10.1002/wer.70352
Vancouver
McNamara PJ, Calteux J, Redman E, Adkins C, McKnight T, Moss L, et al. PFAS Removal During Pyrolysis of Biosolids Is Affected by Initial PFAS Concentration and Pyrolysis Efficiency. Water Environment Research. 2026;98(4). doi:10.1002/wer.70352
BibTeX
@article{McNamara2026,
author = {McNamara, Patrick J and Calteux, Jessica and Redman, Eric and Adkins, Courtney and McKnight, Taryn and Moss, Lynne and Ayala, Rosely and Ishida, Serina and Liu, Zhongzhe},
title = {PFAS Removal During Pyrolysis of Biosolids Is Affected by Initial PFAS Concentration and Pyrolysis Efficiency},
journal = {Water Environment Research},
year = {2026},
volume = {98},
number = {4},
doi = {10.1002/wer.70352}
}
EUVIMED