Fachartikel in der Zeitschrift Water Environment Research, online erschienen am 22.12.2025. Verfasst von Gayeon Park und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Environmental Engineering, Mokpo National University, Jeonnam, South Korea. Hauptthemen laut MEDLINE: Seawater, Boron, Water Pollutants, Chemical, Water Purification. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study evaluates the fixed‐bed column performance of poly(GMA‐glucamine) for selective boron removal and recovery from natural seawater. Batch adsorption tests confirmed pseudo‐second‐order kinetics ( R 2 = 0.999) with a boron uptake of 16.3 mg/g, governed by chemisorption through vicinal diol–borate complexation. Fixed‐bed experiments at varying height‐to‐diameter ratios (5.2, 9.1, and 13.7) showed improved breakthrough performance with increased bed depth. Breakthrough data were well described by the Bohart–Adams ( R 2 > 0.993) and Wolborska ( R 2 = 0.957–0.989) models, indicating combined control by surface reaction and external mass transfer. BDST analysis exhibited strong linearity ( R 2 = 0.994–0.999), with bed capacities of 3872–3999 mg/L and critical bed depths of 4.7–9.2 mm, supporting compact column design. Regeneration using 1.0 M HCl achieved 97.5% desorption efficiency and 390 mg/L boron recovery (78‐fold enrichment), with over 95% capacity retained after five cycles. The resin exhibited excellent stability across salinity (30–45‰) and temperature (15–35 °C) ranges. The results provide a comprehensive techno‐economic and environmental evaluation based on real operational data, offering LCA‐level insight into system sustainability. Poly(GMA‐glucamine) demonstrates scalable, durable, and cost‐effective performance, enabling both boron recovery and sustainable seawater desalination.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SeawaterBoronWater Pollutants, ChemicalWater PurificationAdsorptionOsmosisKinetics

Stichwörter der Autor:innen

boron recoverybreakthrough modelingfixed‐bed columnscale‐up designseawater desalination

Substanzen

BoronWater Pollutants, Chemical

Autor:innen und Institutionen

  • Department of Environmental Engineering, Mokpo National University, Jeonnam, South Korea.
  • Institute of Engineering Research, Seoul National University, Seoul, South Korea.

ORCID-Profile: Hyunju Park

Zitieren

APA

Park, G., Park, H., & Na, C. K. (2026). Fixed‐Bed Column Performance of Poly‐GMA‐Glucamine for Boron Recovery in Seawater Reverse Osmosis: Breakthrough Analysis and Scale‐Up Design Parameters. Water Environment Research, 98(1). https://doi.org/10.1002/wer.70251

Vancouver

Park G, Park H, Na CK. Fixed‐Bed Column Performance of Poly‐GMA‐Glucamine for Boron Recovery in Seawater Reverse Osmosis: Breakthrough Analysis and Scale‐Up Design Parameters. Water Environment Research. 2026;98(1). doi:10.1002/wer.70251

BibTeX
@article{Park2026,
  author = {Park, Gayeon and Park, Hyunju and Na, Choon-Ki},
  title = {Fixed‐Bed Column Performance of Poly‐GMA‐Glucamine for Boron Recovery in Seawater Reverse Osmosis: Breakthrough Analysis and Scale‐Up Design Parameters},
  journal = {Water Environment Research},
  year = {2026},
  volume = {98},
  number = {1},
  doi = {10.1002/wer.70251}
}
Kostenlos starten →