Automated data transfer for digital twin applications: Two case studies
Water Environment Research · 2024
DOI: 10.1002/wer.11074 ↗Kurz gefasst
Fachartikel in der Zeitschrift Water Environment Research, 2024. Verfasst von Hanna Molin und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Industrial Electrical Engineering and Automation (IEA), Department of Biomedical Engineering, Lund University, Lund, Sweden. Hauptthemen laut MEDLINE: Automation. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Stockholm Vatten och Avfall AB, Käppala Association, Syvab.
Abstract (Originalsprache)
Digital twins have been gaining an immense interest in various fields over the last decade. Bringing conventional process simulation models into (near) real time are thought to provide valuable insights for operators, decision makers, and stakeholders in many industries. The objective of this paper is to describe two methods for implementing digital twins at water resource recovery facilities and highlight and discuss their differences and preferable use situations, with focus on the automated data transfer from the real process. Case 1 uses a tailor‐made infrastructure for automated data transfer between the facility and the digital twin. Case 2 uses edge computing for rapid automated data transfer. The data transfer lag from process to digital twin is low compared to the simulation frequency in both systems. The presented digital twin objectives can be achieved using either of the presented methods. The method of Case 1 is better suited for automatic recalibration of model parameters, although workarounds exist for the method in Case 2. The method of Case 2 is well suited for objectives such as soft sensors due to its integration with the SCADA system and low latency. The objective of the digital twin, and the required latency of the system, should guide the choice of method. Practitioner Points Various methods can be used for automated data transfer between the physical system and a digital twin. Delays in the data transfer differ depending on implementation method. The digital twin objective determines the required simulation frequency. Implementation method should be chosen based on the required simulation frequency.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Industrial Electrical Engineering and Automation (IEA), Department of Biomedical Engineering, Lund University, Lund, Sweden.
- IVL Swedish Environmental Research Institute, Stockholm, Sweden.
- RISE Research Institutes of Sweden AB, Gothenburg, Sweden.
- Division of Systems and Control, Department of Information Technology, Uppsala University, Uppsala, Sweden.
- Gemit Solutions AB, Stockholm, Sweden.
ORCID-Profile: Hanna Molin
Förderung
- Stockholm Vatten och Avfall AB
- Käppala Association
- Syvab
- IVL Swedish Environmental Research Institute
- Svenskt Vatten
- Swedish Research Council Formas
- RISE Research Institutes of Sweden
- Nordvästra Skånes Vatten och Avlopp
Zitieren
APA
Molin, H., Wärff, C., Lindblom, E., Arnell, M., Carlsson, B., Mattsson, P., Bäckman, J., & Jeppsson, U. (2024). Automated data transfer for digital twin applications: Two case studies. Water Environment Research. https://doi.org/10.1002/wer.11074
Vancouver
Molin H, Wärff C, Lindblom E, Arnell M, Carlsson B, Mattsson P, et al. Automated data transfer for digital twin applications: Two case studies. Water Environment Research. 2024. doi:10.1002/wer.11074
BibTeX
@article{Molin2024,
author = {Molin, Hanna and Wärff, Christoffer and Lindblom, Erik and Arnell, Magnus and Carlsson, Bengt and Mattsson, Per and Bäckman, Jonas and Jeppsson, Ulf},
title = {Automated data transfer for digital twin applications: Two case studies},
journal = {Water Environment Research},
year = {2024},
doi = {10.1002/wer.11074}
}
EUVIMED