EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Changes in Doppler Ultrasonography and Echotexture Parameters in Cows During the Last 10 Days of Pregnancy

Murat Can Demir iD, Merve Sena Demir iD, Burak Büyükbaki iD, Mushap Kuru iD, Semra Kaya iD, Cihan Kaçar iD

Veterinary Medicine and Science · 2025

DOI: 10.1002/vms3.70256 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Veterinary Medicine and Science, 2025. Verfasst von Murat Can Demir und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Obstetrics and Gynaecology, Faculty of Veterinary, University of Kafkas, Kars, Türkiye. Hauptthemen laut MEDLINE: Ultrasonography, Doppler, Placenta, Uterine Artery, Pregnancy, Animal. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 63 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to investigate changes in Doppler sonographic measurements of uterine artery blood flow to the placenta, as well as variations in placentome echotexture/perfusion and myometrial thickness in cows during the last 10 days of pregnancy.

Methods

The study utilized eight pregnant Brown Swiss cows. In assessing the echotexture of the placentome and myometrium, the mean grey value (MGV) was measured, along with the placentome area and myometrium thickness (MT). For placentome perfusion analysis and spectral analysis of the uterine artery, parameters, including pulse rate (PR), resistance index (RI), blood flow velocity (BFVe), blood flow volume (BFVo) and diameter (DM), were recorded.

Results

During the last 10 days of pregnancy, the placentome area and MT exhibited a declining trend from the start of sampling until delivery ( p = 0.005). Both placentome and myometrium MGV showed an increasing trend over the study period ( p < 0.001). Placentome perfusion decreased significantly 3 days prior to delivery ( p < 0.05). A significant difference was observed in BFVe/DM in the uterine arteries between pregnant and non‐pregnant horns. RI ( p = 0.005) and PR ( p = 0.009) values changed significantly over time.

Conclusions

As a result, differences in ultrasonographic findings were observed during the last 10 days of pregnancy in cows. It can be concluded that changes, particularly in the final 2 days, may be associated with placental maturation mechanisms.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ultrasonography, DopplerPlacentaUterine ArteryPregnancy, AnimalAnimalsFemalePregnancyCattleMyometriumBlood Flow Velocity

Stichwörter der Autor:innen

Dopplercowmean grey valueplacental maturationplacental perfusionuterine artery

Autor:innen und Institutionen

  • Department of Obstetrics and Gynaecology, Faculty of Veterinary, University of Kafkas, Kars, Türkiye.
  • Department of Wildlife and Ecology, Faculty of Veterinary, University of Kafkas, Kars, Türkiye.

ORCID-Profile: Murat Can Demir, Merve Sena Demir, Burak Büyükbaki, Mushap Kuru, Semra Kaya, Cihan Kaçar

Zitieren

APA

Demir, M. C., Demir, M. S., Büyükbaki, B., Kuru, M., Kaya, S., & Kaçar, C. (2025). Changes in Doppler Ultrasonography and Echotexture Parameters in Cows During the Last 10 Days of Pregnancy. Veterinary Medicine and Science. https://doi.org/10.1002/vms3.70256

Vancouver

Demir MC, Demir MS, Büyükbaki B, Kuru M, Kaya S, Kaçar C. Changes in Doppler Ultrasonography and Echotexture Parameters in Cows During the Last 10 Days of Pregnancy. Veterinary Medicine and Science. 2025. doi:10.1002/vms3.70256

BibTeX
@article{Demir2025,
  author = {Demir, Murat Can and Demir, Merve Sena and Büyükbaki, Burak and Kuru, Mushap and Kaya, Semra and Kaçar, Cihan},
  title = {Changes in Doppler Ultrasonography and Echotexture Parameters in Cows During the Last 10 Days of Pregnancy},
  journal = {Veterinary Medicine and Science},
  year = {2025},
  doi = {10.1002/vms3.70256}
}
Kostenlos starten →